TY - JOUR
T1 - Investigations on the influence of nozzle arrangement on the pre-cooling effect for the natural draft dry cooling tower
AU - Sun, Yubiao
AU - Guan, Zhiqiang
AU - Gurgenci, Hal
AU - Hooman, Kamel
AU - Li, Xiaoxiao
N1 - Publisher Copyright:
© 2017 Elsevier Ltd
PY - 2018/2/5
Y1 - 2018/2/5
N2 - Natural draft dry cooling tower (NDDCT), with little water usage, is a primary choice for power plants in dried regions. However, the increased ambient temperature during summer days decreases the cooling performance of NDDCT. Inlet air pre-cooling is used to alleviate the tower deterioration by making use of water evaporation to remove excess heat from inlet air. To achieve the maximal cooling effect, the injection heights, radial distances and injection directions of employed nozzle LNN1.5 were studied based on the CFD results. The study shows that lower nozzle placement can cool the central part of the radiator while the higher one cools the middle part. Additionally, the increasing extended length can boost the evaporation process of generated spray. Moreover, the upward and co-flow injections have poorer performance than the downward and counter-flow injections. Furthermore, an introduction of wall cover changes the flow field and drives the pre-cooled air flow through the edge of radiator. Since the wall cover reduces the blockage caused by the near-wall vortex the resultant low-temperature region move outwardly.
AB - Natural draft dry cooling tower (NDDCT), with little water usage, is a primary choice for power plants in dried regions. However, the increased ambient temperature during summer days decreases the cooling performance of NDDCT. Inlet air pre-cooling is used to alleviate the tower deterioration by making use of water evaporation to remove excess heat from inlet air. To achieve the maximal cooling effect, the injection heights, radial distances and injection directions of employed nozzle LNN1.5 were studied based on the CFD results. The study shows that lower nozzle placement can cool the central part of the radiator while the higher one cools the middle part. Additionally, the increasing extended length can boost the evaporation process of generated spray. Moreover, the upward and co-flow injections have poorer performance than the downward and counter-flow injections. Furthermore, an introduction of wall cover changes the flow field and drives the pre-cooled air flow through the edge of radiator. Since the wall cover reduces the blockage caused by the near-wall vortex the resultant low-temperature region move outwardly.
KW - Natural draft dry cooling tower
KW - Spray cooling
KW - Wall cover
UR - http://www.scopus.com/inward/record.url?scp=85034743167&partnerID=8YFLogxK
U2 - 10.1016/j.applthermaleng.2017.10.171
DO - 10.1016/j.applthermaleng.2017.10.171
M3 - Article
AN - SCOPUS:85034743167
SN - 1359-4311
VL - 130
SP - 979
EP - 996
JO - Applied Thermal Engineering
JF - Applied Thermal Engineering
ER -