Intra-operative risk analysis of robot-assisted liver tumor coagulation therapy systems

Shaoli Liu*, Jianhua Liu

*此作品的通讯作者

科研成果: 期刊稿件文章同行评审

摘要

An effective real-time intra-operative risk analysis algorithm for robot-assisted liver tumor coagulation therapy systems was proposed to solve the problem that the systems risk analysis still depends on two-dimensional image information in celiac intervention therapy due to the lack of quantitative information during intra-operative monitoring. The key to the algorithm is that the shortest distance between the moving needles and the important tissues and organs in the abdominal cavity, and the corresponding time are transformed into the convex optimization problem for analysis. This convex optimization problem is solved based on the interior point method. The simulation results demonstrated that the real-time risk analysis algorithm based on the interior point method was effective, real-time, and universal. The collision detection between multiple convex bodies can be realized once the obstacles and needles are expressed for the third-order continuously differentiable implicit function, which can provide effective quantitative risk analysis information to surgeons for surgery monitoring.

源语言英语
页(从-至)1166-1172
页数7
期刊Gaojishu Tongxin/High Technology Letters
23
11
DOI
出版状态已出版 - 11月 2013

指纹

探究 'Intra-operative risk analysis of robot-assisted liver tumor coagulation therapy systems' 的科研主题。它们共同构成独一无二的指纹。

引用此