TY - JOUR
T1 - Inter/intra-frame constrained vascular segmentation in X-ray angiographic image sequence
AU - Song, Shuang
AU - Du, Chenbing
AU - Chen, Ying
AU - Ai, Danni
AU - Song, Hong
AU - Huang, Yong
AU - Wang, Yongtian
AU - Yang, Jian
N1 - Publisher Copyright:
© 2019 The Author(s).
PY - 2019/12/19
Y1 - 2019/12/19
N2 - Background: Automatic vascular segmentation in X-ray angiographic image sequence is of crucial interest, for instance, for better quantifying coronary arteries in diagnostic and interventional procedures. Methods: A novel inter/intra-frame constrained vascular segmentation method is proposed to automatically segment vessels in coronary X-ray angiographic image sequence. First, a morphological filter operator is applied to remove structures undergoing the respiratory motion from the original image sequence. Second, an inter-frame constrained robust principal component analysis (RPCA) is utilized to remove the quasi-static structures from the image sequence. Third, an intra-frame constrained RPCA is employed to smooth the final extracted vascular sequence. Fourth, a multi-feature fusion is designed to improve the vascular contrast and the final vascular segmentation is realized by thresholding-based method. Results: Experiments are conducted on 22 clinical X-ray angiographic image sequences. The global and local contrast-to-noise ratio of the proposed method are 6.6344 and 4.2882, respectively. And the precision, sensitivity and F1 value are 0.7378, 0.7960 and 0.7658, respectively. It demonstrates that our method is effective and robust for vascular segmentation from image sequence. Conclusions: The proposed method is effective to remove non-vascular structures, reduce motion artefacts and other non-uniform illumination caused noises. Also, the proposed method is online which can just process one image per time without re-optimizing the model.
AB - Background: Automatic vascular segmentation in X-ray angiographic image sequence is of crucial interest, for instance, for better quantifying coronary arteries in diagnostic and interventional procedures. Methods: A novel inter/intra-frame constrained vascular segmentation method is proposed to automatically segment vessels in coronary X-ray angiographic image sequence. First, a morphological filter operator is applied to remove structures undergoing the respiratory motion from the original image sequence. Second, an inter-frame constrained robust principal component analysis (RPCA) is utilized to remove the quasi-static structures from the image sequence. Third, an intra-frame constrained RPCA is employed to smooth the final extracted vascular sequence. Fourth, a multi-feature fusion is designed to improve the vascular contrast and the final vascular segmentation is realized by thresholding-based method. Results: Experiments are conducted on 22 clinical X-ray angiographic image sequences. The global and local contrast-to-noise ratio of the proposed method are 6.6344 and 4.2882, respectively. And the precision, sensitivity and F1 value are 0.7378, 0.7960 and 0.7658, respectively. It demonstrates that our method is effective and robust for vascular segmentation from image sequence. Conclusions: The proposed method is effective to remove non-vascular structures, reduce motion artefacts and other non-uniform illumination caused noises. Also, the proposed method is online which can just process one image per time without re-optimizing the model.
KW - Multi-feature
KW - Vascular enhancement
KW - Vascular segmentation
KW - X-ray angiographic image sequence
UR - http://www.scopus.com/inward/record.url?scp=85076957211&partnerID=8YFLogxK
U2 - 10.1186/s12911-019-0966-x
DO - 10.1186/s12911-019-0966-x
M3 - Article
C2 - 31856807
AN - SCOPUS:85076957211
SN - 1472-6947
VL - 19
JO - BMC Medical Informatics and Decision Making
JF - BMC Medical Informatics and Decision Making
M1 - 270
ER -