TY - JOUR
T1 - Improving blast protection of double-layered system for infilled masonry wall in frame structure
AU - Zhang, Xuejian
AU - Wang, Xiaojuan
AU - Zhou, Hongyuan
AU - Zhang, Wenxue
AU - Song, Tianyi
AU - Wang, Yonghui
AU - Zhang, Hong
N1 - Publisher Copyright:
© 2023 Elsevier Ltd
PY - 2023/9
Y1 - 2023/9
N2 - To dissipate a large amount of blast energy as well as realize a reasonable load transfer to the beam and column instead of the vulnerable wall in the frame structure, this study employs a novel double-layered system to protect the infilled vulnerable masonry wall to resist blast loads. The system comprises a sacrificial cladding directly exposed to the blast to dissipate energy and connectors to facilitate load transfer and mitigation. Based on the quasi-static compressive test on the connector, the field blast test on the sacrificial cladding and frame structure with an infilled masonry wall, their respective numerical models are established and validated with ANSYS/LS-DYNA, which facilitates the model establishment of the frame structure protected by the double-layered system subjected to blast load. The numerical results indicate that the system effectively mitigates the damage to the masonry wall and reduces the load transferred to the frame compared to that without protection. However, large bending deformation of the sacrificial cladding may still result in collision damage to the vulnerable wall which makes it difficult to be applied in engineering practice. To improve the protective performance of the double-layered system and reduce the possibility of the occurrence of a collision between the sacrificial cladding and the wall, several measures, including connector layout optimization, rear plate strengthening with stiffeners, and appropriate connector height determination have been proposed. The numerical results demonstrate that installing connectors at four edges, adding 5 × 5 stiffeners on the rear surface of the sacrificial cladding, and appropriately designing the height of the connector can significantly enhance the double-layered system's protective performance, which has practical significance in protecting vulnerable masonry wall in frame structure from blast loads.
AB - To dissipate a large amount of blast energy as well as realize a reasonable load transfer to the beam and column instead of the vulnerable wall in the frame structure, this study employs a novel double-layered system to protect the infilled vulnerable masonry wall to resist blast loads. The system comprises a sacrificial cladding directly exposed to the blast to dissipate energy and connectors to facilitate load transfer and mitigation. Based on the quasi-static compressive test on the connector, the field blast test on the sacrificial cladding and frame structure with an infilled masonry wall, their respective numerical models are established and validated with ANSYS/LS-DYNA, which facilitates the model establishment of the frame structure protected by the double-layered system subjected to blast load. The numerical results indicate that the system effectively mitigates the damage to the masonry wall and reduces the load transferred to the frame compared to that without protection. However, large bending deformation of the sacrificial cladding may still result in collision damage to the vulnerable wall which makes it difficult to be applied in engineering practice. To improve the protective performance of the double-layered system and reduce the possibility of the occurrence of a collision between the sacrificial cladding and the wall, several measures, including connector layout optimization, rear plate strengthening with stiffeners, and appropriate connector height determination have been proposed. The numerical results demonstrate that installing connectors at four edges, adding 5 × 5 stiffeners on the rear surface of the sacrificial cladding, and appropriately designing the height of the connector can significantly enhance the double-layered system's protective performance, which has practical significance in protecting vulnerable masonry wall in frame structure from blast loads.
KW - Blast load
KW - Double-layered system
KW - Energy absorption
KW - Load transfer
KW - Protective performance
UR - http://www.scopus.com/inward/record.url?scp=85163821605&partnerID=8YFLogxK
U2 - 10.1016/j.tws.2023.110953
DO - 10.1016/j.tws.2023.110953
M3 - Article
AN - SCOPUS:85163821605
SN - 0263-8231
VL - 190
JO - Thin-Walled Structures
JF - Thin-Walled Structures
M1 - 110953
ER -