TY - JOUR
T1 - Graphene oxide-based colorimetric/fluorescence dual-mode immunochromatography assay for simultaneous ultrasensitive detection of respiratory virus and bacteria in complex samples
AU - Cheng, Xiaodan
AU - Yang, Xingsheng
AU - Tu, Zhijie
AU - Rong, Zhen
AU - Wang, Chongwen
AU - Wang, Shengqi
N1 - Publisher Copyright:
© 2023 Elsevier B.V.
PY - 2023/10/5
Y1 - 2023/10/5
N2 - A point-of-care testing biosensor that supports direct, sensitive, and simultaneous identification of bacteria and virus is still lacking. In this study, an ultrasensitive immunochromatography assay (ICA) with colorimetric/fluorescence dual-signal output was proposed for flexible and accurate detection of respiratory virus and bacteria in complex samples. Colorimetric AuNPs of 16 nm and two layers of quantum dots (QDs) were coated onto the surface of monolayer graphene oxide (GO) layer by layer to form a multilayered dual-signal nanofilm. This material not only can generate strong colorimetric and fluorescence signals for ICA analysis but also can provide larger surface area, better stability, and superior dispersibility than conventional spherical nanomaterials. Two test lines were built onto the ICA strip to simultaneously detect common respiratory virus influenza A and respiratory bacteria Streptococcus pneumoniae. The dual-signal mode of assay greatly broadened the applied range of ICA method, in which the colorimetric mode allows for quick determination of virus/bacteria and the fluorescence mode ensures the highly sensitive and quantitative detection of target pathogens with detection limits down to 891 copies/mL and 17 cells/mL, respectively. The proposed dual-mode ICA can also be applied directly for real biological and environment samples, which suggests its great potential for field application.
AB - A point-of-care testing biosensor that supports direct, sensitive, and simultaneous identification of bacteria and virus is still lacking. In this study, an ultrasensitive immunochromatography assay (ICA) with colorimetric/fluorescence dual-signal output was proposed for flexible and accurate detection of respiratory virus and bacteria in complex samples. Colorimetric AuNPs of 16 nm and two layers of quantum dots (QDs) were coated onto the surface of monolayer graphene oxide (GO) layer by layer to form a multilayered dual-signal nanofilm. This material not only can generate strong colorimetric and fluorescence signals for ICA analysis but also can provide larger surface area, better stability, and superior dispersibility than conventional spherical nanomaterials. Two test lines were built onto the ICA strip to simultaneously detect common respiratory virus influenza A and respiratory bacteria Streptococcus pneumoniae. The dual-signal mode of assay greatly broadened the applied range of ICA method, in which the colorimetric mode allows for quick determination of virus/bacteria and the fluorescence mode ensures the highly sensitive and quantitative detection of target pathogens with detection limits down to 891 copies/mL and 17 cells/mL, respectively. The proposed dual-mode ICA can also be applied directly for real biological and environment samples, which suggests its great potential for field application.
KW - Colorimetric/fluorescence dual mode
KW - Film-like dual-signal nanotag
KW - Immunochromatography assay
KW - Influenza A
KW - Streptococcus pneumoniae
UR - http://www.scopus.com/inward/record.url?scp=85167954011&partnerID=8YFLogxK
U2 - 10.1016/j.jhazmat.2023.132192
DO - 10.1016/j.jhazmat.2023.132192
M3 - Article
C2 - 37541116
AN - SCOPUS:85167954011
SN - 0304-3894
VL - 459
JO - Journal of Hazardous Materials
JF - Journal of Hazardous Materials
M1 - 132192
ER -