TY - JOUR
T1 - Fluorescent Photoelectric Detection of Peroxide Explosives Based on a Time Series Similarity Measurement Method
AU - Shi, Weize
AU - Wang, Yabin
N1 - Publisher Copyright:
© 2023 by the authors.
PY - 2023/10
Y1 - 2023/10
N2 - Due to the characteristics of peroxide explosives, which are difficult to detect via conventional detection methods and have high explosive power, a fluorescent photoelectric detection system based on fluorescence detection technology was designed in this study to achieve the high-sensitivity detection of trace peroxide explosives in practical applications. Through actual measurement experiments and numerical simulation methods, the derivative dynamic time warping (DDTW) algorithm and the Spearman correlation coefficient were used to calculate the DDTW–Spearman distance to achieve time series correlation measurements. The detection sensitivity of triacetone triperoxide (TATP) and H2O2 was studied, and the detection of organic substances of acetone, acetylene, ethanol, ethyl acetate, and petroleum ether was carried out. The stability and specific detection ability of the fluorescent photoelectric detection system were determined. The research results showed that the fluorescence photoelectric detection system can effectively identify the detection data of TATP, H2O2, acetone, acetonitrile, ethanol, ethyl acetate, and petroleum ether. The detection limit of 0.01 mg/mL of TATP and 0.0046 mg/mL of H2O2 was less than 10 ppb. The time series similarity measurement method improves the analytical capabilities of fluorescence photoelectric detection technology.
AB - Due to the characteristics of peroxide explosives, which are difficult to detect via conventional detection methods and have high explosive power, a fluorescent photoelectric detection system based on fluorescence detection technology was designed in this study to achieve the high-sensitivity detection of trace peroxide explosives in practical applications. Through actual measurement experiments and numerical simulation methods, the derivative dynamic time warping (DDTW) algorithm and the Spearman correlation coefficient were used to calculate the DDTW–Spearman distance to achieve time series correlation measurements. The detection sensitivity of triacetone triperoxide (TATP) and H2O2 was studied, and the detection of organic substances of acetone, acetylene, ethanol, ethyl acetate, and petroleum ether was carried out. The stability and specific detection ability of the fluorescent photoelectric detection system were determined. The research results showed that the fluorescence photoelectric detection system can effectively identify the detection data of TATP, H2O2, acetone, acetonitrile, ethanol, ethyl acetate, and petroleum ether. The detection limit of 0.01 mg/mL of TATP and 0.0046 mg/mL of H2O2 was less than 10 ppb. The time series similarity measurement method improves the analytical capabilities of fluorescence photoelectric detection technology.
KW - DDTW
KW - Spearman correlation coefficient
KW - fluorescent photoelectric detection
KW - peroxide explosives
KW - time series
UR - http://www.scopus.com/inward/record.url?scp=85174070596&partnerID=8YFLogxK
U2 - 10.3390/s23198264
DO - 10.3390/s23198264
M3 - Article
C2 - 37837094
AN - SCOPUS:85174070596
SN - 1424-8220
VL - 23
JO - Sensors
JF - Sensors
IS - 19
M1 - 8264
ER -