TY - JOUR
T1 - Field measurement method for ultrasonic transducer based on inverse Abel transform
AU - Kong, Tao
AU - Xu, Chun Guang
AU - Xiao, Ding Guo
PY - 2011/6
Y1 - 2011/6
N2 - A new reflection approach for field distribution measurement of ultrasonic transducers was investigated. Instead of a point-like reflection target (rigid sphere) or thin wires (line-like targets), a line response function of experimental knife-edge distribution combined with the inverse Abel transforms was used to estimate the lateral beam distributions of ultrasonic transducers. The measurement steps were as follows: 1 A knife-edge was scanned perpendicularly to acoustic beam axis of the transducer using an ultrasonic C-scan system to obtain its ultrasonic image line response function, 2 the transverse beam distribution was solved by the inverse Abel transforms, and 3 experiments were performed to obtain the lateral beam profiles of two transducers, with and without focus, and the results were compared with those from a hydrophone. The results showed that this method was effective for ultrasonic field measurement and could be as a substitute for hydrophone in most cases.
AB - A new reflection approach for field distribution measurement of ultrasonic transducers was investigated. Instead of a point-like reflection target (rigid sphere) or thin wires (line-like targets), a line response function of experimental knife-edge distribution combined with the inverse Abel transforms was used to estimate the lateral beam distributions of ultrasonic transducers. The measurement steps were as follows: 1 A knife-edge was scanned perpendicularly to acoustic beam axis of the transducer using an ultrasonic C-scan system to obtain its ultrasonic image line response function, 2 the transverse beam distribution was solved by the inverse Abel transforms, and 3 experiments were performed to obtain the lateral beam profiles of two transducers, with and without focus, and the results were compared with those from a hydrophone. The results showed that this method was effective for ultrasonic field measurement and could be as a substitute for hydrophone in most cases.
KW - Inverse Abel transforms
KW - Knife-edge distribution
KW - Ultrasonic filed measurement
UR - http://www.scopus.com/inward/record.url?scp=79960054706&partnerID=8YFLogxK
M3 - Article
AN - SCOPUS:79960054706
SN - 1004-0579
VL - 20
SP - 211
EP - 215
JO - Journal of Beijing Institute of Technology (English Edition)
JF - Journal of Beijing Institute of Technology (English Edition)
IS - 2
ER -