Fault tolerant control of dual-rotor PMSM under open-circuit fault conditions

Yumeng Li, Jing Zhao*, Zhen Chen, Xiangdong Liu, Hao Chen

*此作品的通讯作者

科研成果: 书/报告/会议事项章节会议稿件同行评审

1 引用 (Scopus)

摘要

Compared with the traditional single rotor motor, the dual-rotor permanent magnet synchronous motor (PMSM) has a higher torque density due to the existence of two working air-gaps. As there are slots on the inside and outside surfaces of stator core, two sets of three-phase winding can be installed, which can be driven in series or parallel. This will result in the different torque performances of dual-rotor PMSM under open-circuit fault conditions, so they are investigated in this paper. Then, the current control strategy is applied to adjust the open-circuit fault, based on the instantaneous power balance theory. The investigations are verified by finite analysis results.

源语言英语
主期刊名2014 17th International Conference on Electrical Machines and Systems, ICEMS 2014
出版商Institute of Electrical and Electronics Engineers Inc.
1227-1232
页数6
ISBN(电子版)9781479951611
DOI
出版状态已出版 - 2014
活动2014 17th International Conference on Electrical Machines and Systems, ICEMS 2014 - Hangzhou, 中国
期限: 22 10月 201425 10月 2014

出版系列

姓名2014 17th International Conference on Electrical Machines and Systems, ICEMS 2014

会议

会议2014 17th International Conference on Electrical Machines and Systems, ICEMS 2014
国家/地区中国
Hangzhou
时期22/10/1425/10/14

指纹

探究 'Fault tolerant control of dual-rotor PMSM under open-circuit fault conditions' 的科研主题。它们共同构成独一无二的指纹。

引用此