TY - JOUR
T1 - Experimental study on the technology optimization of clear ice thickness detection on horizontal cold plate surface by using microwave resonance
AU - Shi, Han
AU - Zhen, Zekang
AU - Yu, Sirui
AU - Song, Mengjie
AU - Zhang, Long
AU - Zhang, Xuan
N1 - Publisher Copyright:
© 2024
PY - 2024/12
Y1 - 2024/12
N2 - The accumulation of snow and ice has the potential to have a negative impact on numerous industries if it is not accurately detected and processed in real-time. Microwave resonators have gained interest as durable and reliable ice detectors. To detect the thickness of clear ice slices on a horizontal cold plate surface, a capacitively coupled split-ring resonant sensor was experimentally investigated. To ascertain the efficacy of the sensor, plexiglass with similar relative permittivity to ice was firstly tested. The effect of the plexiglass plate thickness on the resonance amplitude of the transmission scatter parameter was found to be monotonic in the range of 16.8 mm thickness, thereby demonstrating the ability of the sensor to accurately measure plate thickness. Then, the effect of different thicknesses of clear ice slices within 17.0 mm on the resonance parameters was tested under constant temperature. The resonant amplitude decreased by 46.55% from −4.13 dB to −6.05 dB, as the thickness of the clear ice slice gradually increased from 2.5 mm to 17.0 mm. A model for the detection of ice thickness based on the analysis of theoretical principles and experimental data was developed. The ice thickness could be detected accurately within a range of 17.0 mm at temperatures between −3 and −20 °C, with a maximum deviation of 5.66% in the detection of ice thickness. This study validates the application of the sensor to detect ice thickness, such as on ships, roads and aircraft.
AB - The accumulation of snow and ice has the potential to have a negative impact on numerous industries if it is not accurately detected and processed in real-time. Microwave resonators have gained interest as durable and reliable ice detectors. To detect the thickness of clear ice slices on a horizontal cold plate surface, a capacitively coupled split-ring resonant sensor was experimentally investigated. To ascertain the efficacy of the sensor, plexiglass with similar relative permittivity to ice was firstly tested. The effect of the plexiglass plate thickness on the resonance amplitude of the transmission scatter parameter was found to be monotonic in the range of 16.8 mm thickness, thereby demonstrating the ability of the sensor to accurately measure plate thickness. Then, the effect of different thicknesses of clear ice slices within 17.0 mm on the resonance parameters was tested under constant temperature. The resonant amplitude decreased by 46.55% from −4.13 dB to −6.05 dB, as the thickness of the clear ice slice gradually increased from 2.5 mm to 17.0 mm. A model for the detection of ice thickness based on the analysis of theoretical principles and experimental data was developed. The ice thickness could be detected accurately within a range of 17.0 mm at temperatures between −3 and −20 °C, with a maximum deviation of 5.66% in the detection of ice thickness. This study validates the application of the sensor to detect ice thickness, such as on ships, roads and aircraft.
KW - Clear ice thickness detection
KW - Microwave resonators
KW - Microwave scatter parameter
KW - Split-ring resonant sensor
UR - http://www.scopus.com/inward/record.url?scp=85203407512&partnerID=8YFLogxK
U2 - 10.1016/j.coldregions.2024.104308
DO - 10.1016/j.coldregions.2024.104308
M3 - Article
AN - SCOPUS:85203407512
SN - 0165-232X
VL - 228
JO - Cold Regions Science and Technology
JF - Cold Regions Science and Technology
M1 - 104308
ER -