TY - JOUR
T1 - Experimental Study on the Performance of RT 25 to be Used as Ambient Energy Storage
AU - Iten, Muriel
AU - Liu, Shuli
N1 - Publisher Copyright:
© 2015 The Authors.
PY - 2015
Y1 - 2015
N2 - The proposed experimental work intends to analyse the thermal performance of a TES unit incorporated into a ventilation system under different working conditions. The influences of the air inlet temperature and velocity on the air outlet temperature and heat transfer rate were investigated The air inlet temperature used for the solidification of RT25 were 10°C, 12°C and 14°C and for the melting 34°C, 36°C and 38°C. The selected air inlet velocities were the same for the melting and solidification process: 0.5 m/s, 1.4 m/s and 2.5 m/s. The results suggest that an increase of the air inlet velocity reduces linearly the temperature difference between the air inlet and outlet for the solidification process of the RT25. Contrary, for the melting of the RT25, increasing the air inlet velocity does not reduce the temperature difference linearly, increasing the air inlet temperature furthermore from 36°C to 38°C did not affect the melting time. The air inlet temperature plays a significant role on the melting process, reducing linearly the air inlet and outlet temperature difference and the heat transfer rate, however does not influence the solidification process, similar air inlet and outlet temperature difference and the heat transfer rate were obtained for all condition.Thus, air inlet velocity and air inlet temperature have to be carefully balanced to optimize the whole running cycle of both melting and solidification processes.
AB - The proposed experimental work intends to analyse the thermal performance of a TES unit incorporated into a ventilation system under different working conditions. The influences of the air inlet temperature and velocity on the air outlet temperature and heat transfer rate were investigated The air inlet temperature used for the solidification of RT25 were 10°C, 12°C and 14°C and for the melting 34°C, 36°C and 38°C. The selected air inlet velocities were the same for the melting and solidification process: 0.5 m/s, 1.4 m/s and 2.5 m/s. The results suggest that an increase of the air inlet velocity reduces linearly the temperature difference between the air inlet and outlet for the solidification process of the RT25. Contrary, for the melting of the RT25, increasing the air inlet velocity does not reduce the temperature difference linearly, increasing the air inlet temperature furthermore from 36°C to 38°C did not affect the melting time. The air inlet temperature plays a significant role on the melting process, reducing linearly the air inlet and outlet temperature difference and the heat transfer rate, however does not influence the solidification process, similar air inlet and outlet temperature difference and the heat transfer rate were obtained for all condition.Thus, air inlet velocity and air inlet temperature have to be carefully balanced to optimize the whole running cycle of both melting and solidification processes.
KW - Paraffin RT25
KW - Phase change material
KW - Thermal energy storage
KW - Thermal performance
UR - http://www.scopus.com/inward/record.url?scp=84994691718&partnerID=8YFLogxK
U2 - 10.1016/j.egypro.2015.02.119
DO - 10.1016/j.egypro.2015.02.119
M3 - Conference article
AN - SCOPUS:84994691718
SN - 1876-6102
VL - 70
SP - 229
EP - 240
JO - Energy Procedia
JF - Energy Procedia
T2 - 3rd International Conference on Solar Heating and Cooling for Buildings and Industry, SHC 2014
Y2 - 13 October 2014 through 15 October 2014
ER -