TY - JOUR
T1 - Experimental study on an absorption refrigeration system driven by temperature-distributed heat sources
AU - Xu, Qingyu
AU - Lu, Ding
AU - Chen, Gaofei
AU - Guo, Hao
AU - Dong, Xueqiang
AU - Zhao, Yanxing
AU - Shen, Jun
AU - Gong, Maoqiong
N1 - Publisher Copyright:
© 2018
PY - 2019/3/1
Y1 - 2019/3/1
N2 - The absorption refrigeration system driven by low grade heat sources, especially the waste heat sources, becomes more and more attractive in recent decades. However, most traditional absorption systems cannot achieve a high utilization rate of the waste heat with limited heat capacity. These systems are usually designed to obtain heat in the generator, which means that the waste heat sources cannot be utilized to the temperature lower than the generator temperature. This paper proposed a new structure heated by heat conduction oil in the generator and electric heating rings around the stripping section. This structure can simulate the temperature-distributed heat sources when the electric heating rings work. It can also simulate a traditional generator when the electric heating rings do not work. Influences of different heat distributions are analyzed in detail in this paper. The results show that the heat sources utilization rate will increase with the increase of the heat in the stripping section, while the coefficient of performance will be negatively affected by the increasing heat in the stripping section. By optimizing the heating structure, the coefficient of performance can be similar to that of a traditional system when the heat is just added in the middle and lower part of stripping section. The optimum utilization rate of heat sources in this test model can reach 1.8 times to that of a traditional system. Under this heating model, the lowest temperature required in the heating section is 82 °C when the heat conduction oil inlet temperature is 169 °C. It is much lower than the temperature inside the generator, which is 137.3 °C.
AB - The absorption refrigeration system driven by low grade heat sources, especially the waste heat sources, becomes more and more attractive in recent decades. However, most traditional absorption systems cannot achieve a high utilization rate of the waste heat with limited heat capacity. These systems are usually designed to obtain heat in the generator, which means that the waste heat sources cannot be utilized to the temperature lower than the generator temperature. This paper proposed a new structure heated by heat conduction oil in the generator and electric heating rings around the stripping section. This structure can simulate the temperature-distributed heat sources when the electric heating rings work. It can also simulate a traditional generator when the electric heating rings do not work. Influences of different heat distributions are analyzed in detail in this paper. The results show that the heat sources utilization rate will increase with the increase of the heat in the stripping section, while the coefficient of performance will be negatively affected by the increasing heat in the stripping section. By optimizing the heating structure, the coefficient of performance can be similar to that of a traditional system when the heat is just added in the middle and lower part of stripping section. The optimum utilization rate of heat sources in this test model can reach 1.8 times to that of a traditional system. Under this heating model, the lowest temperature required in the heating section is 82 °C when the heat conduction oil inlet temperature is 169 °C. It is much lower than the temperature inside the generator, which is 137.3 °C.
KW - Absorption refrigeration
KW - Ammonia-water
KW - Generator
KW - Heat sources utilization
KW - Temperature-distributed heat load
UR - http://www.scopus.com/inward/record.url?scp=85059555313&partnerID=8YFLogxK
U2 - 10.1016/j.energy.2018.12.159
DO - 10.1016/j.energy.2018.12.159
M3 - Article
AN - SCOPUS:85059555313
SN - 0360-5442
VL - 170
SP - 471
EP - 479
JO - Energy
JF - Energy
ER -