A hybrid cryogenic refrigerator that combines the magnetic refrigeration effect with the GM refrigeration effect has been experimentally studied. ErNi and TmCuAl, which have large magnetocaloric effects, are used to fill the second (low-temperature) stage regenerator of a GM refrigerator and put in a magnetic field varying from 0 to 1.1 T. A phase angle α is defined as the phase between the varying magnetic field and displacer movement and can be tuned in order to find the best timing between the magnetic refrigeration and the GM refrigeration cycle. Efforts have also been made to suppress eddy current losses induced due to the varying magnetic field through the cold head. A phase angle of 60° was found to generate best cooling performance through experiments. A minimal no-load temperature of 3.5 K was obtained at 0.5 Hz while the GM refrigeration alone can only generate a no-load temperature of 4.2 K.
源语言 | 英语 |
---|---|
页(从-至) | 99-104 |
页数 | 6 |
期刊 | Cryogenics |
卷 | 99 |
DOI | |
出版状态 | 已出版 - 4月 2019 |
已对外发布 | 是 |