TY - JOUR
T1 - Energy transfer procession in an air source heat pump unit during defrosting with melted frost locally drainage in its multi-circuit outdoor coil
AU - Song, Mengjie
AU - Chaobin, Dang
AU - Ning, Mao
AU - Shiming, Deng
N1 - Publisher Copyright:
© 2018 Elsevier B.V.
PY - 2018/4/1
Y1 - 2018/4/1
N2 - Air source heat pump (ASHP) units are widely used in recent years, and reverse cycle defrosting becomes the most popular method to solve their undesired frosting problem. During defrosting, a transient and nonlinear heat and mass transfer procession, the metal energy stored in the indoor and outdoor coils are varying as their temperature fluctuations. On the other hand, authors have previously confirmed the effects of melted frost and metal energy storage on system defrosting performance. However, detailed energy transfer procession without melted frost influence is still not identified. This fundamental problem directly affects the development and modification of two coils in a novel ASHP unit or an existing one. Consequently, basing on frost evenly accumulated on each circuit's surface, two cases were thereby designed in this study. Experimental results show that, the heating supply of indoor air thermal energy contributed about 80% of the total energy usage for defrosting, nearly 90% of energy consumed on frost melting and ambient air heating, respectively. After the total area of outdoor coil was enlarged by 50%, the metal energy storage effect was changed from −0.44% to −3.67%. Meanwhile, defrosting efficiency was improved by 11.66%, from 47.13% to 58.79%. Contributions of this study can effectively guide the design optimization of an ASHP unit, improve occupant's thermal comfort and promote the energy saving in buildings and industry.
AB - Air source heat pump (ASHP) units are widely used in recent years, and reverse cycle defrosting becomes the most popular method to solve their undesired frosting problem. During defrosting, a transient and nonlinear heat and mass transfer procession, the metal energy stored in the indoor and outdoor coils are varying as their temperature fluctuations. On the other hand, authors have previously confirmed the effects of melted frost and metal energy storage on system defrosting performance. However, detailed energy transfer procession without melted frost influence is still not identified. This fundamental problem directly affects the development and modification of two coils in a novel ASHP unit or an existing one. Consequently, basing on frost evenly accumulated on each circuit's surface, two cases were thereby designed in this study. Experimental results show that, the heating supply of indoor air thermal energy contributed about 80% of the total energy usage for defrosting, nearly 90% of energy consumed on frost melting and ambient air heating, respectively. After the total area of outdoor coil was enlarged by 50%, the metal energy storage effect was changed from −0.44% to −3.67%. Meanwhile, defrosting efficiency was improved by 11.66%, from 47.13% to 58.79%. Contributions of this study can effectively guide the design optimization of an ASHP unit, improve occupant's thermal comfort and promote the energy saving in buildings and industry.
KW - Air source heat pump
KW - Frosting evenness value
KW - Melted frost locally drainage
KW - Metal energy storage
KW - Multi-circuit outdoor coil
KW - Reverse cycle defrosting
UR - http://www.scopus.com/inward/record.url?scp=85041459296&partnerID=8YFLogxK
U2 - 10.1016/j.enbuild.2018.01.004
DO - 10.1016/j.enbuild.2018.01.004
M3 - Article
AN - SCOPUS:85041459296
SN - 0378-7788
VL - 164
SP - 109
EP - 120
JO - Energy and Buildings
JF - Energy and Buildings
ER -