TY - JOUR
T1 - Energy efficiency assessment of hydrogen recirculation ejectors for proton exchange membrane fuel cell (PEMFC) system
AU - Ding, Hongbing
AU - Dong, Yuanyuan
AU - Zhang, Yu
AU - Yang, Yan
AU - Wen, Chuang
N1 - Publisher Copyright:
© 2023 The Author(s)
PY - 2023/9/15
Y1 - 2023/9/15
N2 - The ejector is the core component for hydrogen recirculation in a proton exchange membrane fuel cell (PEMFC) system. However, in the past, the computational fluid dynamics (CFD) simulation of the ejector mainly focused on the influence of the change of the structural parameters on its performance, while the research on phase change condensation was lacking. Here, we proposed a two-phase flow model integrating the non-equilibrium phase change conservation equations and four categories of entropy transport equations, which analysed the phase change characteristics and the influence of different primary pressures on the property of ejector and internal entropy and exergy under the dry and wet gas models. We validated that the wet gas model has a good prediction ability with an MRE of only 2.53%. There was a significant difference between the dry and wet gas models, for example, the dry gas model predicted a larger Mach number and entrainment ratio, while the temperature and pressure were less than that of the wet gas model. Finally, the entropy and exergy were analysed, and the dry gas model overestimated the entropy generation, i.e, when the pressure of the primary inlet raised to 5.0 bar, the entropy generation overestimated by the dry gas model had reached 138.66 J kg-1K−1. The exergy destruction and exergy destruction ratio both increased with the rise of primary pressure. The dry gas model overestimated the exergy destruction and exergy destruction ratio, and the maximum overestimated values can reach 41.83 kJ/kg and 15.83%, respectively.
AB - The ejector is the core component for hydrogen recirculation in a proton exchange membrane fuel cell (PEMFC) system. However, in the past, the computational fluid dynamics (CFD) simulation of the ejector mainly focused on the influence of the change of the structural parameters on its performance, while the research on phase change condensation was lacking. Here, we proposed a two-phase flow model integrating the non-equilibrium phase change conservation equations and four categories of entropy transport equations, which analysed the phase change characteristics and the influence of different primary pressures on the property of ejector and internal entropy and exergy under the dry and wet gas models. We validated that the wet gas model has a good prediction ability with an MRE of only 2.53%. There was a significant difference between the dry and wet gas models, for example, the dry gas model predicted a larger Mach number and entrainment ratio, while the temperature and pressure were less than that of the wet gas model. Finally, the entropy and exergy were analysed, and the dry gas model overestimated the entropy generation, i.e, when the pressure of the primary inlet raised to 5.0 bar, the entropy generation overestimated by the dry gas model had reached 138.66 J kg-1K−1. The exergy destruction and exergy destruction ratio both increased with the rise of primary pressure. The dry gas model overestimated the exergy destruction and exergy destruction ratio, and the maximum overestimated values can reach 41.83 kJ/kg and 15.83%, respectively.
KW - Ejector
KW - Exergy destruction
KW - Hydrogen
KW - Non-equilibrium condensation
KW - PEMFC
KW - Proton exchange membrane fuel cell
UR - http://www.scopus.com/inward/record.url?scp=85161331048&partnerID=8YFLogxK
U2 - 10.1016/j.apenergy.2023.121357
DO - 10.1016/j.apenergy.2023.121357
M3 - Article
AN - SCOPUS:85161331048
SN - 0306-2619
VL - 346
JO - Applied Energy
JF - Applied Energy
M1 - 121357
ER -