Electron tomography simulator with realistic 3D phantom for evaluation of acquisition, alignment and reconstruction methods

Xiaohua Wan, Tsvi Katchalski, Christopher Churas, Sreya Ghosh, Sebastien Phan, Albert Lawrence*, Yu Hao, Ziying Zhou, Ruijuan Chen, Yu Chen, Fa Zhang, Mark H. Ellisman

*此作品的通讯作者

科研成果: 期刊稿件文章同行评审

1 引用 (Scopus)
Plum Print visual indicator of research metrics
  • Citations
    • Citation Indexes: 1
  • Captures
    • Readers: 22
see details

摘要

Because of the significance of electron microscope tomography in the investigation of biological structure at nanometer scales, ongoing improvement efforts have been continuous over recent years. This is particularly true in the case of software developments. Nevertheless, verification of improvements delivered by new algorithms and software remains difficult. Current analysis tools do not provide adaptable and consistent methods for quality assessment. This is particularly true with images of biological samples, due to image complexity, variability, low contrast and noise. We report an electron tomography (ET) simulator with accurate ray optics modeling of image formation that includes curvilinear trajectories through the sample, warping of the sample and noise. As a demonstration of the utility of our approach, we have concentrated on providing verification of the class of reconstruction methods applicable to wide field images of stained plastic-embedded samples. Accordingly, we have also constructed digital phantoms derived from serial block face scanning electron microscope images. These phantoms are also easily modified to include alignment features to test alignment algorithms. The combination of more realistic phantoms with more faithful simulations facilitates objective comparison of acquisition parameters, alignment and reconstruction algorithms and their range of applicability. With proper phantoms, this approach can also be modified to include more complex optical models, including distance-dependent blurring and phase contrast functions, such as may occur in cryotomography.

源语言英语
页(从-至)103-115
页数13
期刊Journal of Structural Biology
198
2
DOI
出版状态已出版 - 5月 2017
已对外发布

指纹

探究 'Electron tomography simulator with realistic 3D phantom for evaluation of acquisition, alignment and reconstruction methods' 的科研主题。它们共同构成独一无二的指纹。

引用此

Wan, X., Katchalski, T., Churas, C., Ghosh, S., Phan, S., Lawrence, A., Hao, Y., Zhou, Z., Chen, R., Chen, Y., Zhang, F., & Ellisman, M. H. (2017). Electron tomography simulator with realistic 3D phantom for evaluation of acquisition, alignment and reconstruction methods. Journal of Structural Biology, 198(2), 103-115. https://doi.org/10.1016/j.jsb.2017.04.002