Effects of leakage cooling on IP rotor disc and root in 600MW steam turbine

Jiandao Yang, Mingxu Qi, Daiwei Zhou, Hong Yang

科研成果: 会议稿件论文同行评审

摘要

Numerical simulation is performed on the first two stages of IP cylinder of a 600MW steam turbine using CFD and CHT methods. Cooling effects of HP cylinder leakage steam on IP cylinder rotor is investigated and flow behavior of the leakage steam in cooling passages is studied, with configurations of seals, root bottom gaps and diaphragm-to-disc gaps included. Efficient cooling effects are achieved on the rotor and blade root of the first stage, with highest temperature decrease being up to 90K. No obvious cooling effects are found on the second stage rotor blade and rotor disc. Maximum temperature of rotor groove for first and second stage appears at trailing and leading side of its meshing surface with root flat, with value being 796K and 803K separately, which are 41K and 34K lower than the temperature of IP cylinder fresh mean steam.

源语言英语
出版状态已出版 - 2009
活动9th International Conference on Power Engineering, ICOPE 2009 - Kobe, 日本
期限: 16 11月 200920 11月 2009

会议

会议9th International Conference on Power Engineering, ICOPE 2009
国家/地区日本
Kobe
时期16/11/0920/11/09

指纹

探究 'Effects of leakage cooling on IP rotor disc and root in 600MW steam turbine' 的科研主题。它们共同构成独一无二的指纹。

引用此