摘要
A novel approach of ECG baseline wander correction based on mean-median filter and empirical mode decomposition is presented in this paper. The low frequency parts of the original signals were removed by the mean median filter in a nonlinear way to obtain the baseline wander estimation, then its series of IMFs were sifted by t-test after empirical mode decomposition. The proposed method, tested by the ECG signals in MIT-BIH Arrhythmia database and European ST-T database, is more effective compared with other baseline wander removal methods.
源语言 | 英语 |
---|---|
页(从-至) | 365-371 |
页数 | 7 |
期刊 | Bio-Medical Materials and Engineering |
卷 | 24 |
期 | 1 |
DOI | |
出版状态 | 已出版 - 2014 |