TY - JOUR
T1 - Direct Quantification of the Effect of Ammonium on Aerosol Droplet pH
AU - Huang, Qishen
AU - Wei, Haoran
AU - Marr, Linsey C.
AU - Vikesland, Peter J.
N1 - Publisher Copyright:
© 2020 American Chemical Society.
PY - 2021/1/5
Y1 - 2021/1/5
N2 - Ammonium is an important atmospheric constituent that dictates many environmental processes. The impact of the ammonium ion concentration on 10-50 μm aerosol droplet pH was quantified using pH nanoprobes and surface-enhanced Raman spectroscopy (SERS). Sample solutions were prepared by mixing 1 M ammonium sulfate (AS), ammonium nitrate (AN), sodium sulfate (SS), or sodium nitrate (SN) solutions with 1 M phosphate buffer (PB) at different volume ratios. Stable pH values were measured for pure PB, AS, and AN droplets at different concentrations. The centroid pH of 1 M PB droplets was μ11, but when PB was systematically replaced with ammonium (AS- or AN-PB), the centroid pH within the droplets decreased from ≈11 to 5.5. Such a decrease was not observed in sodium (SS- or SN-PB) droplets, and no pH differences were observed between sulfate and nitrate salts. Ammonia partitioning to the gas phase in ammonium-containing droplets was evaluated to be negligible. Raman sulfate peak (μ980 cm-1) intensity measurements and surface tension measurements were conducted to investigate changes in ion distribution. The pH difference between ammonium-containing droplets and ammonium-free droplets is attributed to the alteration of the ion distribution in the presence of ammonium.
AB - Ammonium is an important atmospheric constituent that dictates many environmental processes. The impact of the ammonium ion concentration on 10-50 μm aerosol droplet pH was quantified using pH nanoprobes and surface-enhanced Raman spectroscopy (SERS). Sample solutions were prepared by mixing 1 M ammonium sulfate (AS), ammonium nitrate (AN), sodium sulfate (SS), or sodium nitrate (SN) solutions with 1 M phosphate buffer (PB) at different volume ratios. Stable pH values were measured for pure PB, AS, and AN droplets at different concentrations. The centroid pH of 1 M PB droplets was μ11, but when PB was systematically replaced with ammonium (AS- or AN-PB), the centroid pH within the droplets decreased from ≈11 to 5.5. Such a decrease was not observed in sodium (SS- or SN-PB) droplets, and no pH differences were observed between sulfate and nitrate salts. Ammonia partitioning to the gas phase in ammonium-containing droplets was evaluated to be negligible. Raman sulfate peak (μ980 cm-1) intensity measurements and surface tension measurements were conducted to investigate changes in ion distribution. The pH difference between ammonium-containing droplets and ammonium-free droplets is attributed to the alteration of the ion distribution in the presence of ammonium.
UR - http://www.scopus.com/inward/record.url?scp=85097868534&partnerID=8YFLogxK
U2 - 10.1021/acs.est.0c07394
DO - 10.1021/acs.est.0c07394
M3 - Article
C2 - 33296596
AN - SCOPUS:85097868534
SN - 0013-936X
VL - 55
SP - 778
EP - 787
JO - Environmental Science and Technology
JF - Environmental Science and Technology
IS - 1
ER -