TY - JOUR
T1 - Determination of Endogenous Neurotoxin 1-Acetyl-6,7-Dihydroxyl-1,2,3,4-Tetrahydroisoquinoline in Rat Substantia Nigra by High Performance Liquid Chromatography-Electrospray Ionization-Tandem Mass Spectrometry
AU - Xie, Bingjie
AU - Xiong, Yan
AU - Ullah, Kaleem
AU - Peng, Lei
AU - Lin, Fankai
AU - Zhang, Zhensong
AU - Qing, Hong
AU - Deng, Yulin
PY - 2013/12
Y1 - 2013/12
N2 - The endogenous neurotoxin, 1-acetyl-6,7-dihydroxyl-1,2,3,4 -tetrahydro isoquinoline (ADTIQ), is acatecholamine isoquinoline, indicating its possible involvement in Parkinson's disease. Moreover, it has been assumed to be a bridge between diabetes and Parkinson's disease because metabolic synthesis resembles glucose metabolism. Therefore, the accurate determination of ADTIQ could play an important role in diagnosis of diabetes and Parkinson's disease. Herein, a sensitive and precise method was established to determine ADTIQ by high performance liquid chromatography-electrospray ionization-tandem mass spectrometry in multiple reaction monitoring mode. The [M+H]+ precursor product ions for ADTIQ were 208.1/190.1 and linear range of calibration curve was from 1.0 to 250.0 nM. The limit of detection and limit of quantification of the developed method were 0.2 nM and 1 nM, respectively. The inter-day, intra-day precision, accuracy, and recoveries were acceptable for biological samples. Furthermore, the reported method was used to determine ADTIQ levels in the substantia nigra of rats. The results indicated that the developed method was highly sensitive and accurate for the determination of ADTIQ.
AB - The endogenous neurotoxin, 1-acetyl-6,7-dihydroxyl-1,2,3,4 -tetrahydro isoquinoline (ADTIQ), is acatecholamine isoquinoline, indicating its possible involvement in Parkinson's disease. Moreover, it has been assumed to be a bridge between diabetes and Parkinson's disease because metabolic synthesis resembles glucose metabolism. Therefore, the accurate determination of ADTIQ could play an important role in diagnosis of diabetes and Parkinson's disease. Herein, a sensitive and precise method was established to determine ADTIQ by high performance liquid chromatography-electrospray ionization-tandem mass spectrometry in multiple reaction monitoring mode. The [M+H]+ precursor product ions for ADTIQ were 208.1/190.1 and linear range of calibration curve was from 1.0 to 250.0 nM. The limit of detection and limit of quantification of the developed method were 0.2 nM and 1 nM, respectively. The inter-day, intra-day precision, accuracy, and recoveries were acceptable for biological samples. Furthermore, the reported method was used to determine ADTIQ levels in the substantia nigra of rats. The results indicated that the developed method was highly sensitive and accurate for the determination of ADTIQ.
KW - 1-Acetyl-6,7-dihydroxyl-1,2,3,4-tetrahydroisoquinoline
KW - LC-MS/MS
KW - Liquid chromatography
KW - Mass spectrometry
UR - http://www.scopus.com/inward/record.url?scp=84889013272&partnerID=8YFLogxK
U2 - 10.1080/00032719.2013.814057
DO - 10.1080/00032719.2013.814057
M3 - Article
AN - SCOPUS:84889013272
SN - 0003-2719
VL - 46
SP - 2828
EP - 2834
JO - Analytical Letters
JF - Analytical Letters
IS - 18
ER -