TY - JOUR
T1 - Detection and analysis of cerebral aneurysms based on X-ray rotational angiography - the CADA 2020 challenge
AU - Ivantsits, Matthias
AU - Goubergrits, Leonid
AU - Kuhnigk, Jan Martin
AU - Huellebrand, Markus
AU - Bruening, Jan
AU - Kossen, Tabea
AU - Pfahringer, Boris
AU - Schaller, Jens
AU - Spuler, Andreas
AU - Kuehne, Titus
AU - Jia, Yizhuan
AU - Li, Xuesong
AU - Shit, Suprosanna
AU - Menze, Bjoern
AU - Su, Ziyu
AU - Ma, Jun
AU - Nie, Ziwei
AU - Jain, Kartik
AU - Liu, Yanfei
AU - Lin, Yi
AU - Hennemuth, Anja
N1 - Publisher Copyright:
© 2021 Elsevier B.V.
PY - 2022/4
Y1 - 2022/4
N2 - The Cerebral Aneurysm Detection and Analysis (CADA) challenge was organized to support the development and benchmarking of algorithms for detecting, analyzing, and risk assessment of cerebral aneurysms in X-ray rotational angiography (3DRA) images. 109 anonymized 3DRA datasets were provided for training, and 22 additional datasets were used to test the algorithmic solutions. Cerebral aneurysm detection was assessed using the F2 score based on recall and precision, and the fit of the delivered bounding box was assessed using the distance to the aneurysm. The segmentation quality was measured using the Jaccard index and a combination of different surface distance measures. Systematic errors were analyzed using volume correlation and bias. Rupture risk assessment was evaluated using the F2 score. 158 participants from 22 countries registered for the CADA challenge. The U-Net-based detection solutions presented by the community show similar accuracy compared to experts (F2 score 0.92), with a small number of missed aneurysms with diameters smaller than 3.5 mm. In addition, the delineation of these structures, based on U-Net variations, is excellent, with a Jaccard score of 0.92. The rupture risk estimation methods achieved an F2 score of 0.71. The performance of the detection and segmentation solutions is equivalent to that of human experts. The best results are obtained in rupture risk estimation by combining different image-based, morphological, and computational fluid dynamic parameters using machine learning methods. Furthermore, we evaluated the best methods pipeline, from detecting and delineating the vessel dilations to estimating the risk of rupture. The chain of these methods achieves an F2-score of 0.70, which is comparable to applying the risk prediction to the ground-truth delineation (0.71).
AB - The Cerebral Aneurysm Detection and Analysis (CADA) challenge was organized to support the development and benchmarking of algorithms for detecting, analyzing, and risk assessment of cerebral aneurysms in X-ray rotational angiography (3DRA) images. 109 anonymized 3DRA datasets were provided for training, and 22 additional datasets were used to test the algorithmic solutions. Cerebral aneurysm detection was assessed using the F2 score based on recall and precision, and the fit of the delivered bounding box was assessed using the distance to the aneurysm. The segmentation quality was measured using the Jaccard index and a combination of different surface distance measures. Systematic errors were analyzed using volume correlation and bias. Rupture risk assessment was evaluated using the F2 score. 158 participants from 22 countries registered for the CADA challenge. The U-Net-based detection solutions presented by the community show similar accuracy compared to experts (F2 score 0.92), with a small number of missed aneurysms with diameters smaller than 3.5 mm. In addition, the delineation of these structures, based on U-Net variations, is excellent, with a Jaccard score of 0.92. The rupture risk estimation methods achieved an F2 score of 0.71. The performance of the detection and segmentation solutions is equivalent to that of human experts. The best results are obtained in rupture risk estimation by combining different image-based, morphological, and computational fluid dynamic parameters using machine learning methods. Furthermore, we evaluated the best methods pipeline, from detecting and delineating the vessel dilations to estimating the risk of rupture. The chain of these methods achieves an F2-score of 0.70, which is comparable to applying the risk prediction to the ground-truth delineation (0.71).
UR - http://www.scopus.com/inward/record.url?scp=85123264697&partnerID=8YFLogxK
U2 - 10.1016/j.media.2021.102333
DO - 10.1016/j.media.2021.102333
M3 - Short survey
C2 - 34998111
AN - SCOPUS:85123264697
SN - 1361-8415
VL - 77
JO - Medical Image Analysis
JF - Medical Image Analysis
M1 - 102333
ER -