摘要
Using reflective multiple-fold approach can reduce bulk and weight compared with large high-quality optical systems and improved resolution and light collection compared with miniature conventional systems. Air-spaced concentric multi-reflection (ACMR) systems, where two reflective surfaces surround a hollow cavity, are useful for extended focal distance, achromatic aberration, useful for inexpensive, lightweight IR imagers and may lead to convenient designs for broadband or dual-band imagers. Design a camera, which spectral response 2-12 μm, with a total thickness of 30 mm, 130 mm effective focal length, ±4.2 FOV, 0.022 mrad resolution and 68 mm effective aperture, 96 mm outer aperture. Application can fit into the hull or wing of a micro-UAV aircraft, which weight and thickness are tightly constrained, for long range surveillance.
源语言 | 英语 |
---|---|
页(从-至) | 3282-3286 |
页数 | 5 |
期刊 | Optik |
卷 | 124 |
期 | 18 |
DOI | |
出版状态 | 已出版 - 9月 2013 |