TY - JOUR
T1 - Confocal controlled laser-induced breakdown spectroscopy for quantitative detection of cadmium in soil
AU - Li, Angze
AU - Chuai, Xiaojuan
AU - Liu, Yuxin
AU - Qiu, Lirong
AU - Cui, Han
AU - Zhao, Weiqian
N1 - Publisher Copyright:
© 2024
PY - 2024/6
Y1 - 2024/6
N2 - Soil, one of the most precious natural resources on Earth, gradually accumulates heavy metals, inevitably causing significant damage to the ecological environment. Here, we introduce confocal controlled laser induced breakdown spectroscopy (CCLIBS) technology for the quantitative analysis of the heavy metal cadmium in soil for the first time. CCLIBS offers better spatial consistency and stable plasma temperature during sample ablation compared to traditional LIBS, thereby reducing matrix effects to improve the accuracy of the quantitative results. The fluctuation of the spectrum and limit of detection are reduced by 0.6 times and 0.39 times, respectively. An effective prediction model was established using the partial least squares method, with a determination coefficient increased to 0.96. The root mean square error of prediction and average relative error are reduced to 67.67 and 0.20, respectively. These results indicate that CCLIBS provides consistent ablation conditions for elemental quantification and yields reliable test results, which is significant for monitoring heavy metals in the ecological environment and effectively intervene and mitigate environmental contamination.
AB - Soil, one of the most precious natural resources on Earth, gradually accumulates heavy metals, inevitably causing significant damage to the ecological environment. Here, we introduce confocal controlled laser induced breakdown spectroscopy (CCLIBS) technology for the quantitative analysis of the heavy metal cadmium in soil for the first time. CCLIBS offers better spatial consistency and stable plasma temperature during sample ablation compared to traditional LIBS, thereby reducing matrix effects to improve the accuracy of the quantitative results. The fluctuation of the spectrum and limit of detection are reduced by 0.6 times and 0.39 times, respectively. An effective prediction model was established using the partial least squares method, with a determination coefficient increased to 0.96. The root mean square error of prediction and average relative error are reduced to 67.67 and 0.20, respectively. These results indicate that CCLIBS provides consistent ablation conditions for elemental quantification and yields reliable test results, which is significant for monitoring heavy metals in the ecological environment and effectively intervene and mitigate environmental contamination.
KW - Cadmium
KW - Confocal controlled
KW - Laser-induced breakdown spectroscopy
KW - Quantitative detection
UR - http://www.scopus.com/inward/record.url?scp=85191329615&partnerID=8YFLogxK
U2 - 10.1016/j.sab.2024.106931
DO - 10.1016/j.sab.2024.106931
M3 - Article
AN - SCOPUS:85191329615
SN - 0584-8547
VL - 216
JO - Spectrochimica Acta - Part B Atomic Spectroscopy
JF - Spectrochimica Acta - Part B Atomic Spectroscopy
M1 - 106931
ER -