Comparison study of the performance of two kinds of photovoltaic/thermal(PV/T) systems and a PV module at high ambient temperature

Weiqi Yuan, Jie Ji*, Zhaomeng Li, Fan Zhou, Xiao Ren, Xudong Zhao, Shuli Liu

*此作品的通讯作者

科研成果: 期刊稿件文章同行评审

88 引用 (Scopus)

摘要

The power output of a PV system decreases with the operating temperature rising especially in summer. Using the photovoltaic/thermal(PV/T) can help cooling down the operating temperature of the cells. However, there are few studies comparing the performance of different PV/T systems and the PV module at high ambient temperature. In this study, a series of experiments were conducted to compare the performance of the water-pipe-based PV/T, the PV/T with micro-channel heat pipe array(MHPA) and the conventional PV module at high ambient temperature. The results showed that the average cell temperature of the water-pipe-based PV/T, the PV/T with MHPA and the PV module rose in the morning and fell in the afternoon. The temperature of the three systems could be up to 70 °C, 90 °C and 100 °C respectively, while the electrical efficiency of the three systems decreased with the increment in the temperature of the PV cells and ranged from 11.2% to 10%, 9.6%–7.7% and 8.6 to 7.0% respectively. It means that both the water-pipe-based PV/T and the PV/T with MHPA could improve the performance of PV cells. However, in this study the water-pipe-based PV/T had better performance than the PV/T with MHPA.

源语言英语
页(从-至)1153-1161
页数9
期刊Energy
148
DOI
出版状态已出版 - 1 4月 2018
已对外发布

指纹

探究 'Comparison study of the performance of two kinds of photovoltaic/thermal(PV/T) systems and a PV module at high ambient temperature' 的科研主题。它们共同构成独一无二的指纹。

引用此