摘要
The warhead of FAE is needed to have certain operational temperature range. The volume of the mixed fuel in the shell will be changed along with the environmental temperature. So there must be a pre-reserved space in the warhead case. The dimension of the space is determined by several complications, such as the temperature coefficient of the mixed fuel, the intensity of the shell and the mass eccentricity of the warhead. In this paper, the method to calculate the pre-reserved space in the shell is carried out, which satisfies both the safety of the warhead and the launching precision.
源语言 | 英语 |
---|---|
页(从-至) | 5-7 |
页数 | 3 |
期刊 | Huozhayao Xuebao/Chinese Journal of Explosives and Propellants |
卷 | 25 |
期 | 4 |
出版状态 | 已出版 - 2002 |