TY - JOUR
T1 - Color difference threshold determination for acrylic denture base resins
AU - Ren, Jiabao
AU - Lin, Hong
AU - Huang, Qingmei
AU - Liang, Qifan
AU - Zheng, Gang
N1 - Publisher Copyright:
© 2015 -IOS Press and the authors.
PY - 2015
Y1 - 2015
N2 - This study aimed to set evaluation indicators, i.e., perceptibility and acceptability color difference thresholds, of color stability for acrylic denture base resins for a spectrophotometric assessing method, which offered an alternative to the visual method described in ISO 20795-1:2013. A total of 291 disk specimens 50±1 mm in diameter and 0.5±0.1 mm thick were prepared (ISO 20795-1:2013) and processed through radiation tests in an accelerated aging chamber (ISO 7491:2000) for increasing times of 0 to 42 hours. Color alterations were measured with a spectrophotometer and evaluated using the CIE Lab∗ colorimetric system. Color differences were calculated through the CIEDE2000 color difference formula. Thirty-two dental professionals without color vision deficiencies completed perceptibility and acceptability assessments under controlled conditions in vitro. An S-curve fitting procedure was used to analyze the 50:50% perceptibility and acceptability thresholds. Furthermore, perceptibility and acceptability against the differences of the three color attributes, lightness, chroma, and hue, were also investigated. According to the S-curve fitting procedure, the 50:50% perceptibility threshold was 1.71ΔE00 (r2=0.88) and the 50:50% acceptability threshold was 4.00 ΔE00 (r2=0.89). Within the limitations of this study, 1.71/4.00 ΔE00 could be used as perceptibility/acceptability thresholds for acrylic denture base resins.
AB - This study aimed to set evaluation indicators, i.e., perceptibility and acceptability color difference thresholds, of color stability for acrylic denture base resins for a spectrophotometric assessing method, which offered an alternative to the visual method described in ISO 20795-1:2013. A total of 291 disk specimens 50±1 mm in diameter and 0.5±0.1 mm thick were prepared (ISO 20795-1:2013) and processed through radiation tests in an accelerated aging chamber (ISO 7491:2000) for increasing times of 0 to 42 hours. Color alterations were measured with a spectrophotometer and evaluated using the CIE Lab∗ colorimetric system. Color differences were calculated through the CIEDE2000 color difference formula. Thirty-two dental professionals without color vision deficiencies completed perceptibility and acceptability assessments under controlled conditions in vitro. An S-curve fitting procedure was used to analyze the 50:50% perceptibility and acceptability thresholds. Furthermore, perceptibility and acceptability against the differences of the three color attributes, lightness, chroma, and hue, were also investigated. According to the S-curve fitting procedure, the 50:50% perceptibility threshold was 1.71ΔE00 (r2=0.88) and the 50:50% acceptability threshold was 4.00 ΔE00 (r2=0.89). Within the limitations of this study, 1.71/4.00 ΔE00 could be used as perceptibility/acceptability thresholds for acrylic denture base resins.
KW - Acrylic denture base resin
KW - CIEDE2000
KW - acceptability threshold
KW - perceptibility threshold
KW - spectrophotometer
UR - http://www.scopus.com/inward/record.url?scp=84978923771&partnerID=8YFLogxK
U2 - 10.3233/BME-151287
DO - 10.3233/BME-151287
M3 - Article
C2 - 26406023
AN - SCOPUS:84978923771
SN - 0959-2989
VL - 26
SP - S35-S43
JO - Bio-Medical Materials and Engineering
JF - Bio-Medical Materials and Engineering
ER -