CALM: CAscading system with Leaking detection mechanism for medical image segmentation

Jiang Liu*, Joo Hwee Lim, Huiqi Li

*此作品的通讯作者

科研成果: 书/报告/会议事项章节会议稿件同行评审

2 引用 (Scopus)
Plum Print visual indicator of research metrics
  • Citations
    • Citation Indexes: 2
  • Captures
    • Readers: 7
see details

摘要

Medical image segmentation is a challenging process due to possible image over-segmentation and under-segmentation (leaking). The CALM medical image segmentation system is constructed with an innovative scheme that cascades threshold level-set and region-growing segmentation algorithms using Union and Intersection set operators. These set operators help to balance the over-segmentation rate and under-segmentation rate of the system respectively. While adjusting the curvature scalar parameter in the threshold level-set algorithm, we observe that the abrupt change in the size of the segmented areas coincides with the occurrences of possible leaking. Instead of randomly choose a value or use the system default curvature scalar values, this observation prompts us to use the following formula in CALM to automatically decide the optimal curvature values γ to prevent the occurrence of leaking : ∂2S/∂γ2 >= M, where S is the size of the segmented area and M is a large positive number. Motivated for potential applications in organ transplant and analysis, the CALM system is tested on the segmentation of the kidney regions from the Magnetic Resonance images taken from the National University Hospital of Singapore. Due to the nature of MR imaging, low-contrast, weak edges and overlapping regions of adjacent organs at kidney boundaries are frequently seen in the datasets and hence kidney segmentation is prone to leaking. The kidney segmentation accuracy rate achieved by CALM is 22% better compared with those achieved by the component algorithms or the system without leaking detection mechanism. CALM is easy-to-implement and can be applied to many applications besides kidney segmentation.

源语言英语
主期刊名Medical Imaging 2008
主期刊副标题Image Processing
DOI
出版状态已出版 - 2008
已对外发布
活动Medical Imaging 2008: Image Processing - San Diego, CA, 美国
期限: 17 2月 200819 2月 2008

出版系列

姓名Progress in Biomedical Optics and Imaging - Proceedings of SPIE
6914
ISSN(印刷版)1605-7422

会议

会议Medical Imaging 2008: Image Processing
国家/地区美国
San Diego, CA
时期17/02/0819/02/08

指纹

探究 'CALM: CAscading system with Leaking detection mechanism for medical image segmentation' 的科研主题。它们共同构成独一无二的指纹。

引用此

Liu, J., Lim, J. H., & Li, H. (2008). CALM: CAscading system with Leaking detection mechanism for medical image segmentation. 在 Medical Imaging 2008: Image Processing 文章 69143F (Progress in Biomedical Optics and Imaging - Proceedings of SPIE; 卷 6914). https://doi.org/10.1117/12.769635