Approximate Voigt function formula for laser-induced breakdown spectroscopy fitting

Siying Chen, Yiwen Jia, He Chen, Pan Guo, Qixiang Xu, Lifu Wang, Yinchao Zhang*

*此作品的通讯作者

科研成果: 期刊稿件文章同行评审

4 引用 (Scopus)

摘要

Accurate and rapid spectrum fitting is very important for quantitatively analyzing laser-induced breakdown spectroscopy (LIBS). The Voigt function is often used to fit LIBS spectral lines. We propose a new approximate Voigt function formula. Based on the classic Lorentz-Gauss linear combination formula, a summation term was added that contained a specific convolution operation to improve the Voigt function's calculation and fitting accuracy. This formula can be used for the approximate calculation of the Voigt function with an overall accuracy of 0.31% and a full width at half-maximum internal accuracy of 0.25% when the ratio of Lorentzian linewidth to Gaussian linewidth is 1:1. The formula was then applied to LIBS data processing to fit four element spectral lines of calcium (Ca-393.37, 396.85, and 422.67 nm) and potassium (K-766.49 nm). The fitting results showed that this new approximate formula could fit at least seven data points, and compared with the complex plane partition method and the classic linear combination formula, the new formula had better fitting speed and accuracy.

源语言英语
页(从-至)4120-4126
页数7
期刊Applied Optics
60
14
DOI
出版状态已出版 - 10 5月 2021

指纹

探究 'Approximate Voigt function formula for laser-induced breakdown spectroscopy fitting' 的科研主题。它们共同构成独一无二的指纹。

引用此