TY - GEN
T1 - A variable volume loading method to determine the initial emittable concentration of VOC and formaldehyde in building materials
AU - Xiong, Jianyin
AU - Yan, Wei
AU - Zhang, Yinping
AU - Huang, Shaodan
PY - 2011
Y1 - 2011
N2 - The initial emittable VOC and formaldehyde concentration in building materials is a key parameter for characterizing and classifying these materials. This paper proposes a novel variable volume loading (VVL) method to determine this parameter. For the method, variable volumes of the material are put in an airtight chamber separately and perform emission process until equilibrium for each volume, and repeated experiments are performed to reduce measurement error. The presented method has the following features: (a) test the samples under practical conditions; (b) convenient for routine measurements; and (c) require short experimental time. The initial emittable concentrations of formaldehyde, propanal and hexanal in one kind of medium density fiberboard have been measured. In addition, it is found that the ratios of the measured formaldehyde concentration obtained via this method are less than 10% from that using the perforator method, as recommended in the Chinese National Standard.
AB - The initial emittable VOC and formaldehyde concentration in building materials is a key parameter for characterizing and classifying these materials. This paper proposes a novel variable volume loading (VVL) method to determine this parameter. For the method, variable volumes of the material are put in an airtight chamber separately and perform emission process until equilibrium for each volume, and repeated experiments are performed to reduce measurement error. The presented method has the following features: (a) test the samples under practical conditions; (b) convenient for routine measurements; and (c) require short experimental time. The initial emittable concentrations of formaldehyde, propanal and hexanal in one kind of medium density fiberboard have been measured. In addition, it is found that the ratios of the measured formaldehyde concentration obtained via this method are less than 10% from that using the perforator method, as recommended in the Chinese National Standard.
KW - Formaldehyde
KW - Indoor air quality (IAQ)
KW - Initial emittable concentration
KW - Perforator method
KW - Volatile organic compounds (VOC)
UR - http://www.scopus.com/inward/record.url?scp=84880548620&partnerID=8YFLogxK
M3 - Conference contribution
AN - SCOPUS:84880548620
SN - 9781627482721
T3 - 12th International Conference on Indoor Air Quality and Climate 2011
SP - 734
EP - 739
BT - 12th International Conference on Indoor Air Quality and Climate 2011
T2 - 12th International Conference on Indoor Air Quality and Climate 2011
Y2 - 5 June 2011 through 10 June 2011
ER -