TY - JOUR
T1 - A sensitive LC-MS/MS method to quantify loureirin B in rat plasma with application to preclinical pharmacokinetic studies
AU - Li, Yujuan
AU - Li, Yongzhi
AU - Yang, Zhezhe
AU - Xin, Nian
AU - Deng, Yulin
PY - 2009/12/5
Y1 - 2009/12/5
N2 - A novel method for the quantification of loureirin B in rat plasma using high-performance liquid chromatography/tandem mass spectrometry (LC-MS/MS) was developed. Loureirin B and internal standard (buspirone) were extracted by liquid-liquid extraction and separated on a Agilent XDB C18 column (50 mm × 4.6 mm, 5 μm). As mobile phase a binary mixture of methanol (containing 0.1% formic acid)-water (containing 0.1% formic acid) was delivered by a Shimadzu LC-20AD pump in gradient mode at a flow rate of 0.4 ml/min in a run time of 5.0 min. The detector was a Q-trap™ mass spectrometer with an electrospray ionization (ESI) interface operating in the multiple reaction monitoring (MRM) mode. The calibration curve of loureirin B in plasma showed good linearity over the concentration range of 0.08-100 ng/ml. The limit of detection and limit of quantification were 0.03 ng/ml and 0.08 ng/ml, respectively. Intra- and inter-day precisions (as relative standard deviation) in all samples were both within 15%. The validated method was successfully applied to a preliminary pharmacokinetic study of loureirin B in rats. After oral administration of 16 g/kg longxuejie to rats, the main pharmacokinetic parameters tmax, Cmax, t1/2, Ke and AUC0-T were 0.8 h, 7.99 μg/l, 1.94 l h, 0.365/h, and 22.21 μg h/l, respectively.
AB - A novel method for the quantification of loureirin B in rat plasma using high-performance liquid chromatography/tandem mass spectrometry (LC-MS/MS) was developed. Loureirin B and internal standard (buspirone) were extracted by liquid-liquid extraction and separated on a Agilent XDB C18 column (50 mm × 4.6 mm, 5 μm). As mobile phase a binary mixture of methanol (containing 0.1% formic acid)-water (containing 0.1% formic acid) was delivered by a Shimadzu LC-20AD pump in gradient mode at a flow rate of 0.4 ml/min in a run time of 5.0 min. The detector was a Q-trap™ mass spectrometer with an electrospray ionization (ESI) interface operating in the multiple reaction monitoring (MRM) mode. The calibration curve of loureirin B in plasma showed good linearity over the concentration range of 0.08-100 ng/ml. The limit of detection and limit of quantification were 0.03 ng/ml and 0.08 ng/ml, respectively. Intra- and inter-day precisions (as relative standard deviation) in all samples were both within 15%. The validated method was successfully applied to a preliminary pharmacokinetic study of loureirin B in rats. After oral administration of 16 g/kg longxuejie to rats, the main pharmacokinetic parameters tmax, Cmax, t1/2, Ke and AUC0-T were 0.8 h, 7.99 μg/l, 1.94 l h, 0.365/h, and 22.21 μg h/l, respectively.
KW - LC-MS/MS
KW - Longxuejie
KW - Loureirin B
KW - Pharmacokinetics
KW - Rat plasma
UR - http://www.scopus.com/inward/record.url?scp=70349178647&partnerID=8YFLogxK
U2 - 10.1016/j.jpba.2009.07.003
DO - 10.1016/j.jpba.2009.07.003
M3 - Article
C2 - 19660887
AN - SCOPUS:70349178647
SN - 0731-7085
VL - 50
SP - 983
EP - 986
JO - Journal of Pharmaceutical and Biomedical Analysis
JF - Journal of Pharmaceutical and Biomedical Analysis
IS - 5
ER -