摘要
High-performance low temperature detection technologies such as transition edge sensor (TES) and Kinetic Inductance Detectors (KIDS) are becoming more and more mature, which provides an opportunity for astronomers to solve key scientific problems such as “missing baryons” and primordial gravitational wave observation. These kinds of detectors need to work at very low temperatures (generally below 300 mK) to achieve its high sensitivity. As one of the important methods to obtain mK temperature, adiabatic demagnetization refrigerator (ADR) is a good candidate for cooling such high-performance low temperature detectors. In this paper, a two-stage adiabatic demagnetization refrigerator is described, and the refrigerant preparation of paramagnetic salt FAA is introduced. In the preliminary test, the ADR can obtain a temperature below 100 mK, which lays a foundation for subsequent research work.
投稿的翻译标题 | Research on a Two-stage Adiabatic Demagnetization Refrigerator With Minimum Temperature Blow 100 mK |
---|---|
源语言 | 繁体中文 |
页(从-至) | 319-323 |
页数 | 5 |
期刊 | Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics |
卷 | 45 |
期 | 2 |
出版状态 | 已出版 - 2月 2024 |
已对外发布 | 是 |
关键词
- adiabatic demagnetization
- paramagnetic salt pill
- very low temperature