TY - JOUR
T1 - 大气压栅状介质阻挡放电等离子体空气消毒研究
AU - Zhang, Liyang
AU - Guo, Yuntao
AU - Tie, Jinfeng
AU - Fu, Yangyang
AU - Luo, Haiyun
N1 - Publisher Copyright:
© 2024 Science Press. All rights reserved.
PY - 2024/7/31
Y1 - 2024/7/31
N2 - Air purification and disinfection are effective measures for the control of respiratory infectious diseases. Dielectric barrier discharge (DBD) is a promising method for air disinfection due to its high efficiency, large discharge area, and low airflow resistance; however, the research on its disinfection characteristics, factors, and dosage is rarely available in the literature. This paper provides a brief introduction of the recent research progress in air disinfection by grating-like DBD plasma from the Gas Discharge and Plasma Research Team in the Department of Electrical Engineering at Tsinghua University. In terms of disinfection characteristics, the effects of discharge structural parameters, humidity, microbial species, voltage type, and other factors was mainly investigated. It was found that narrowing the gap, increasing electrode size, and increasing airflow humidity could all improve both efficiency and Z-value. When the relative humidity (RH) was 60%, the Z-value could reach 1.68 L/J. The single-pass removal efficiency of MS2 bacteriophage aerosol could reach 99.5%~99.9%. In terms of bactericidal factors, experiments showed that gas-phase short-lived species were the major contributors to bacterial inactivation, with long-lived species accounting for at most 30% of the total bactericidal effect. In terms of disinfection dosage, specific energy density (SED) was proposed as the dose parameter for plasma-based air disinfection. Based on the chemical kinetic model of wet-air plasma discharge, a linear relationship between single-specie dose and power density was discovered, illustrating why SED could be served as the dose. This study can provide theoretical and engineering support for DBD-plasma-based air disinfection.
AB - Air purification and disinfection are effective measures for the control of respiratory infectious diseases. Dielectric barrier discharge (DBD) is a promising method for air disinfection due to its high efficiency, large discharge area, and low airflow resistance; however, the research on its disinfection characteristics, factors, and dosage is rarely available in the literature. This paper provides a brief introduction of the recent research progress in air disinfection by grating-like DBD plasma from the Gas Discharge and Plasma Research Team in the Department of Electrical Engineering at Tsinghua University. In terms of disinfection characteristics, the effects of discharge structural parameters, humidity, microbial species, voltage type, and other factors was mainly investigated. It was found that narrowing the gap, increasing electrode size, and increasing airflow humidity could all improve both efficiency and Z-value. When the relative humidity (RH) was 60%, the Z-value could reach 1.68 L/J. The single-pass removal efficiency of MS2 bacteriophage aerosol could reach 99.5%~99.9%. In terms of bactericidal factors, experiments showed that gas-phase short-lived species were the major contributors to bacterial inactivation, with long-lived species accounting for at most 30% of the total bactericidal effect. In terms of disinfection dosage, specific energy density (SED) was proposed as the dose parameter for plasma-based air disinfection. Based on the chemical kinetic model of wet-air plasma discharge, a linear relationship between single-specie dose and power density was discovered, illustrating why SED could be served as the dose. This study can provide theoretical and engineering support for DBD-plasma-based air disinfection.
KW - air disinfection
KW - atmospheric pressure
KW - bioaerosol
KW - grating-like dielectric barrier discharge
KW - plasma
UR - http://www.scopus.com/inward/record.url?scp=85197871430&partnerID=8YFLogxK
U2 - 10.13336/j.1003-6520.hve.20231161
DO - 10.13336/j.1003-6520.hve.20231161
M3 - 文章
AN - SCOPUS:85197871430
SN - 1003-6520
VL - 50
SP - 2972
EP - 2987
JO - Gaodianya Jishu/High Voltage Engineering
JF - Gaodianya Jishu/High Voltage Engineering
IS - 7
ER -