一种金属电爆炸驱动飞片的速度评估方法

Jun Feng Guo, Qing Xuan Zeng*, Ming Yu Li, Tao Wang

*此作品的通讯作者

科研成果: 期刊稿件文章同行评审

2 引用 (Scopus)

摘要

For exploding foil initiation system (EFIs), an experimental method based on the piezoelectric film (PVDF) was established to estimate the instantaneous velocity of a flyer. The average velocity of a flyer was measured using a PVDF and compared with the theoretical results of the one-dimensional flyer velocity model. The errors of flyer average velocities are within 10%, indicating that the one-dimensional velocity model meets the calculation accuracy requirements. Meanwhile, relationship between average velocity and instantaneous velocity of flyer was analyzed based on theoretical calculations, indicating that instantaneous velocity of flyer is nearly in proportion to average velocity (v=Δv/0.86). Thus, PVDF film method can be utilized to evaluate instantaneous velocity of flyer.

投稿的翻译标题A Method for Evaluating Velocity of Flyer Driven by Metal Electric Exploding
源语言繁体中文
页(从-至)6-8
页数3
期刊Beijing Ligong Daxue Xuebao/Transaction of Beijing Institute of Technology
38
DOI
出版状态已出版 - 1 12月 2018

关键词

  • Flyer velocity
  • Metal electric exploding
  • PVDF film
  • Proportional relationship

指纹

探究 '一种金属电爆炸驱动飞片的速度评估方法' 的科研主题。它们共同构成独一无二的指纹。

引用此

Guo, J. F., Zeng, Q. X., Li, M. Y., & Wang, T. (2018). 一种金属电爆炸驱动飞片的速度评估方法. Beijing Ligong Daxue Xuebao/Transaction of Beijing Institute of Technology, 38, 6-8. https://doi.org/10.15918/j.tbit1001-0645.2018.s2.002