TY - JOUR
T1 - Thermal hazard evaluation of cyclohexanone peroxide in storage and transport
AU - Wei, Tong Tong
AU - Qian, Xin Ming
AU - Yuan, Meng Qi
N1 - Publisher Copyright:
© 2016, Editorial Department of Journal of Northeastern University. All right reserved.
PY - 2016/5/1
Y1 - 2016/5/1
N2 - The most serious thermal decomposition process of CYHPO (cyclohexanone peroxide) is investigated by accelerating rate calorimeter (ARC). The curves of thermal decomposition characteristic parameters versus time for the systems are obtained. The reaction kinetic parameters are calculated by the rate constant method. Modified by the thermal inertia factor, the temperature related parameters at the worst condition is obtained which can reflect the intrinsic thermal hazard of CYHPO. Based on reaction kinetic parameters and Semenov thermal explosion theory, the thermal hazard parameters such as TMRad, θNR, SADT, which are crucial in industry, are calculated. It is proved that the influence of instrumental error of ARC on the results can be neglected. The loading quality of CYHPO should not be exceeding 25 kg and the optimal package is type K for this kind of package, the control temperature and emergency temperature should be lower than 59.7℃.
AB - The most serious thermal decomposition process of CYHPO (cyclohexanone peroxide) is investigated by accelerating rate calorimeter (ARC). The curves of thermal decomposition characteristic parameters versus time for the systems are obtained. The reaction kinetic parameters are calculated by the rate constant method. Modified by the thermal inertia factor, the temperature related parameters at the worst condition is obtained which can reflect the intrinsic thermal hazard of CYHPO. Based on reaction kinetic parameters and Semenov thermal explosion theory, the thermal hazard parameters such as TMRad, θNR, SADT, which are crucial in industry, are calculated. It is proved that the influence of instrumental error of ARC on the results can be neglected. The loading quality of CYHPO should not be exceeding 25 kg and the optimal package is type K for this kind of package, the control temperature and emergency temperature should be lower than 59.7℃.
KW - Accelerating rate calorimeter (ARC)
KW - Cyclohexanone peroxide (CYHPO)
KW - Reaction kinetic parameters
KW - Self-accelerating decomposition temperature
KW - Thermal hazard
UR - http://www.scopus.com/inward/record.url?scp=84971539043&partnerID=8YFLogxK
U2 - 10.3969/j.issn.1005-3026.2016.05.025
DO - 10.3969/j.issn.1005-3026.2016.05.025
M3 - Article
AN - SCOPUS:84971539043
SN - 1005-3026
VL - 37
SP - 726
EP - 730
JO - Dongbei Daxue Xuebao/Journal of Northeastern University
JF - Dongbei Daxue Xuebao/Journal of Northeastern University
IS - 5
ER -