Wu, D., Zhang, H., Chen, J., Wang, S., Chen, J., Wu, Y., Li, Y., & Ren, D. (2013). [Test-retest reliability of Mandarin acceptable noise level]. Lin chuang er bi yan hou tou jing wai ke za zhi = Journal of clinical otorhinolaryngology, head, and neck surgery, 27(7), 352-354, 358.
Wu, Dan ; Zhang, Hua ; Chen, Jianyong et al. / [Test-retest reliability of Mandarin acceptable noise level]. In: Lin chuang er bi yan hou tou jing wai ke za zhi = Journal of clinical otorhinolaryngology, head, and neck surgery. 2013 ; Vol. 27, No. 7. pp. 352-354, 358.
@article{293995f385bf4e53811864ba1b904e3d,
title = "[Test-retest reliability of Mandarin acceptable noise level].",
abstract = "To evaluate test-retest reliability of Mandarin acceptable noise level(M-ANL) test materials. M-ANL was evaluated during three test sessions approximately one week apart, by testing 30 Mandarin-speaking people aged from 21 to 28 with normal aural/oral communication abilities. The participants completed the preference for background noise questionnaire before the first session. Analysis of the test-retest results were administered by SPSS 17.0 (Statistically Package for the Social Sciences Software Version 17.0). ANLs in the three sessions were (8.1 +/- 2.9), (7.4 +/- 2.2), (7.6 +/- 2.5)dB S/N, respectively. The correlation coefficients were 0.722, 0.746 and 0.849 between two of the three sessions. The correlation coefficients of the ANL and 7 questions of the questionnaire were below 0.3. M-ANL test materials are found to have good test-retest reliability. Listeners' preference for background noise is not related to their acceptance of background noise. Listeners cannot accurately assess their ability to accept background noise.",
author = "Dan Wu and Hua Zhang and Jianyong Chen and Shuo Wang and Jing Chen and Yanjun Wu and Yuling Li and Dandan Ren",
year = "2013",
month = apr,
language = "English",
volume = "27",
pages = "352--354, 358",
journal = "Lin chuang er bi yan hou tou jing wai ke za zhi = Journal of clinical otorhinolaryngology, head, and neck surgery",
issn = "1001-1781",
publisher = "Tong ji yi ke da xue Fu shu xie he yi yuan",
number = "7",
}
Wu, D, Zhang, H, Chen, J, Wang, S, Chen, J, Wu, Y, Li, Y & Ren, D 2013, '[Test-retest reliability of Mandarin acceptable noise level].', Lin chuang er bi yan hou tou jing wai ke za zhi = Journal of clinical otorhinolaryngology, head, and neck surgery, vol. 27, no. 7, pp. 352-354, 358.
[Test-retest reliability of Mandarin acceptable noise level]. / Wu, Dan; Zhang, Hua; Chen, Jianyong et al.
In:
Lin chuang er bi yan hou tou jing wai ke za zhi = Journal of clinical otorhinolaryngology, head, and neck surgery, Vol. 27, No. 7, 04.2013, p. 352-354, 358.
Research output: Contribution to journal › Article › peer-review
TY - JOUR
T1 - [Test-retest reliability of Mandarin acceptable noise level].
AU - Wu, Dan
AU - Zhang, Hua
AU - Chen, Jianyong
AU - Wang, Shuo
AU - Chen, Jing
AU - Wu, Yanjun
AU - Li, Yuling
AU - Ren, Dandan
PY - 2013/4
Y1 - 2013/4
N2 - To evaluate test-retest reliability of Mandarin acceptable noise level(M-ANL) test materials. M-ANL was evaluated during three test sessions approximately one week apart, by testing 30 Mandarin-speaking people aged from 21 to 28 with normal aural/oral communication abilities. The participants completed the preference for background noise questionnaire before the first session. Analysis of the test-retest results were administered by SPSS 17.0 (Statistically Package for the Social Sciences Software Version 17.0). ANLs in the three sessions were (8.1 +/- 2.9), (7.4 +/- 2.2), (7.6 +/- 2.5)dB S/N, respectively. The correlation coefficients were 0.722, 0.746 and 0.849 between two of the three sessions. The correlation coefficients of the ANL and 7 questions of the questionnaire were below 0.3. M-ANL test materials are found to have good test-retest reliability. Listeners' preference for background noise is not related to their acceptance of background noise. Listeners cannot accurately assess their ability to accept background noise.
AB - To evaluate test-retest reliability of Mandarin acceptable noise level(M-ANL) test materials. M-ANL was evaluated during three test sessions approximately one week apart, by testing 30 Mandarin-speaking people aged from 21 to 28 with normal aural/oral communication abilities. The participants completed the preference for background noise questionnaire before the first session. Analysis of the test-retest results were administered by SPSS 17.0 (Statistically Package for the Social Sciences Software Version 17.0). ANLs in the three sessions were (8.1 +/- 2.9), (7.4 +/- 2.2), (7.6 +/- 2.5)dB S/N, respectively. The correlation coefficients were 0.722, 0.746 and 0.849 between two of the three sessions. The correlation coefficients of the ANL and 7 questions of the questionnaire were below 0.3. M-ANL test materials are found to have good test-retest reliability. Listeners' preference for background noise is not related to their acceptance of background noise. Listeners cannot accurately assess their ability to accept background noise.
UR - http://www.scopus.com/inward/record.url?scp=84892723637&partnerID=8YFLogxK
M3 - Article
AN - SCOPUS:84892723637
SN - 1001-1781
VL - 27
SP - 352-354, 358
JO - Lin chuang er bi yan hou tou jing wai ke za zhi = Journal of clinical otorhinolaryngology, head, and neck surgery
JF - Lin chuang er bi yan hou tou jing wai ke za zhi = Journal of clinical otorhinolaryngology, head, and neck surgery
IS - 7
ER -
Wu D, Zhang H, Chen J, Wang S, Chen J, Wu Y et al. [Test-retest reliability of Mandarin acceptable noise level]. Lin chuang er bi yan hou tou jing wai ke za zhi = Journal of clinical otorhinolaryngology, head, and neck surgery. 2013 Apr;27(7):352-354, 358.