T1 - Temperature distribution calculation and experiments of Tm:YLF laser
AU - Li, Yan
AU - Zhang, Yixuan
AU - Na, Quanxin
AU - Gao, Mingwei
AU - Gao, Chunqing
N1 - Publisher Copyright:
© 2017, Editorial Board of Journal of Infrared and Laser Engineering. All right reserved.
PY - 2017/5/25
Y1 - 2017/5/25
N2 - The structure of double-crystal four-end pumped Tm:YLF laser was designed and studied. By using steady-state thermal analysis module in the Ansys software, the temperature distributions of the two crystal-clamps and cooling plate were calculated with the heat exchange coefficients of the cooling plate channels given as 1 000 W/(m2·℃), 4 000 W/(m2·℃), 8 000 W/(m2·℃) and 15 000 W/(m2·℃). Meanwhile, the temperature distributions when the cooling-plate was assumed as a TEC cooler with temperatures of 18℃ and 20℃ were calculated, respectively. According to the calculated results, the cooling effect when the cooling-plate was given as medium convection intensity or higher would be equal to the result when taking the cooling-plate as TEC with temperature of 18℃ and 20℃. According to the simulation results, a U-shape Tm:YLF laser was designed pumped by fiber coupled laser diode. The output lasers with powers of 25.9W and 46W were achieved from single crystal and double crystals when the Tm:YLF crystal clamps and cooling plate were directly cooled by 16℃ cold water, corresponding to slope efficiencies of 40.7% and 37.1%, respectively. No over high temperature was observed in the whole experiment. The experiment results indicate that the designed direct conduction cooling system can effectively remove the heat load in single-crystal dual-end and double-crystal four-end pumped Tm: YLF laser.
AB - The structure of double-crystal four-end pumped Tm:YLF laser was designed and studied. By using steady-state thermal analysis module in the Ansys software, the temperature distributions of the two crystal-clamps and cooling plate were calculated with the heat exchange coefficients of the cooling plate channels given as 1 000 W/(m2·℃), 4 000 W/(m2·℃), 8 000 W/(m2·℃) and 15 000 W/(m2·℃). Meanwhile, the temperature distributions when the cooling-plate was assumed as a TEC cooler with temperatures of 18℃ and 20℃ were calculated, respectively. According to the calculated results, the cooling effect when the cooling-plate was given as medium convection intensity or higher would be equal to the result when taking the cooling-plate as TEC with temperature of 18℃ and 20℃. According to the simulation results, a U-shape Tm:YLF laser was designed pumped by fiber coupled laser diode. The output lasers with powers of 25.9W and 46W were achieved from single crystal and double crystals when the Tm:YLF crystal clamps and cooling plate were directly cooled by 16℃ cold water, corresponding to slope efficiencies of 40.7% and 37.1%, respectively. No over high temperature was observed in the whole experiment. The experiment results indicate that the designed direct conduction cooling system can effectively remove the heat load in single-crystal dual-end and double-crystal four-end pumped Tm: YLF laser.
KW - Ansys steady-state thermal analysis
KW - Directly conduction cooled
KW - Tm:YLF laser
UR - http://www.scopus.com/inward/record.url?scp=85027018260&partnerID=8YFLogxK
U2 - 10.3788/IRLA201746.0506001
DO - 10.3788/IRLA201746.0506001
M3 - Article
AN - SCOPUS:85027018260
SN - 1007-2276
VL - 46
JO - Hongwai yu Jiguang Gongcheng/Infrared and Laser Engineering
JF - Hongwai yu Jiguang Gongcheng/Infrared and Laser Engineering
IS - 5
M1 - 0506001
ER -