@inproceedings{3c388f9b58f24d8eb5d00226e06b4dba,
title = "Study on operation control strategy of single piston hydraulic free-piston diesel engine",
abstract = "The operation control strategies of free-piston engine are investigated in this paper. To start the engine, it needs to adjust the compression pressure and the reset valves should cooperate with the frequency control valve to avoid squirm of the piston for hydraulic leakages. The reset valves should be closed before frequency control valve is opened. A piston position feedback modulation control method which can make sure the piston accelerated continuously is presented. It has fixed frequency control valves open signal moment but no fixed frequency control valves closed signal moment, and the closed signal was activated by piston position feedback.",
keywords = "Control strategy, Diesel engine, Feedback control, Free-piston",
author = "Feng Guo and Ying Huang and Zhao, {Chang Lu} and Jia Liu and Zhang, {Zhen Yu}",
year = "2012",
doi = "10.4028/www.scientific.net/AMM.128-129.1044",
language = "English",
isbn = "9783037852842",
series = "Applied Mechanics and Materials",
pages = "1044--1049",
booktitle = "Measuring Technology and Mechatronics Automation IV",
note = "4th International Conference on Measuring Technology and Mechatronics Automation, ICMTMA 2012 ; Conference date: 06-01-2012 Through 07-01-2012",
}