T1 - Straight nano-electrospray ionization and its coupling of mobility capillary electrophoresis to mass spectrometry
AU - Zhang, Fei
AU - Hong, Jie
AU - Xu, Wei
AU - Qu, Feng
N1 - Publisher Copyright:
© 2019
PY - 2020/1/1
Y1 - 2020/1/1
N2 - Mobility capillary electrophoresis (MCE) was developed previously in our group, which has the capabilities of ion separation and biomolecule hydrodynamic radius analysis. The coupling of MCE with mass spectrometry (MS) would greatly improve complex sample identification capability as well as system detection sensitivity. In the present study, a simple and robust ionization source, named as straight nano-electrospray ionization (nanoESI) source was developed, which was applied to couple MCE with MS. A stainless-steel needle attached directly at the end of an MCE capillary was used as the nanoESI emitter, and the connection between this emitter to the liquid flow in the MCE separation channel was established through a liquid bridge. After optimization, this straight nanoESI source enhanced the ion signal intensity by ~10 times when compared with a commercial nanoESI source. The MCE-straight nanoESI-MS system was also characterized in terms of mixture separation and peptide hydrodynamic radius measurements. Compared to our previous work when a UV detector was used in a commercial Lumex CE system (model Capel 105 M, St. Petersburg, Russia), peptides with much lower concentrations could be analyzed (from ~1 mg/mL to ~20 μg/mL) in terms of radius measurement.
AB - Mobility capillary electrophoresis (MCE) was developed previously in our group, which has the capabilities of ion separation and biomolecule hydrodynamic radius analysis. The coupling of MCE with mass spectrometry (MS) would greatly improve complex sample identification capability as well as system detection sensitivity. In the present study, a simple and robust ionization source, named as straight nano-electrospray ionization (nanoESI) source was developed, which was applied to couple MCE with MS. A stainless-steel needle attached directly at the end of an MCE capillary was used as the nanoESI emitter, and the connection between this emitter to the liquid flow in the MCE separation channel was established through a liquid bridge. After optimization, this straight nanoESI source enhanced the ion signal intensity by ~10 times when compared with a commercial nanoESI source. The MCE-straight nanoESI-MS system was also characterized in terms of mixture separation and peptide hydrodynamic radius measurements. Compared to our previous work when a UV detector was used in a commercial Lumex CE system (model Capel 105 M, St. Petersburg, Russia), peptides with much lower concentrations could be analyzed (from ~1 mg/mL to ~20 μg/mL) in terms of radius measurement.
KW - Ion hydrodynamic radius
KW - Mass spectrometry
KW - Mobility capillary electrophoresis
KW - Nano electrospray
UR - http://www.scopus.com/inward/record.url?scp=85069919646&partnerID=8YFLogxK
U2 - 10.1016/j.talanta.2019.120183
DO - 10.1016/j.talanta.2019.120183
M3 - Article
C2 - 31514879
AN - SCOPUS:85069919646
SN - 0039-9140
VL - 206
JO - Talanta
JF - Talanta
M1 - 120183
ER -