Statistical analysis of sensitivity coefficient of variation for mechanical explosive devices

Hui Na Mu*, Qing Jie Jiao, Yu Quan Wen

*Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

3 Citations (Scopus)

Abstract

Through the histogram method and Kolmogorov test, it was obtained that the sensitivity coefficient of variation for D6-2 artillery primer and mechanical explosive devices approximated the normal distribution of (0.34, 0.12), (0.3, 0.12), respectively. Using the upper limit of coefficient of variation for mechanical explosive devices, the reliability design for initiating explosive device was developed. Results indicate that the coefficient of variation determined is practical for the reliability design.

Original languageEnglish
Pages (from-to)212-215
Number of pages4
JournalHanneng Cailiao/Chinese Journal of Energetic Materials
Volume16
Issue number2
Publication statusPublished - Apr 2008

Keywords

  • Coefficient of variation
  • Initiating explosive device
  • Military chemistry and technique of pyrotechnics
  • Reliability design
  • Sensitivity distribution

Fingerprint

Dive into the research topics of 'Statistical analysis of sensitivity coefficient of variation for mechanical explosive devices'. Together they form a unique fingerprint.