Abstract
A standard sample was detected without destruction in this way using individual channel device to realize multi-channels phased control. According to the corresponding the relationship between the arriving time of echo and location of focus, A scan was processed B-mode imaging using signal feature. An approach which the image is binary processed based on threshold is proposed to improve image resolution. MATLAB simulated result shows that the approach can improve image lateral resolution and the accuracy of defect orientation.
Original language | English |
---|---|
Pages (from-to) | 264-267 |
Number of pages | 4 |
Journal | Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument |
Volume | 29 |
Issue number | SUPPL. |
Publication status | Published - Apr 2008 |
Keywords
- B-mode imaging
- Binary processing
- Nondestructive testing
- Ultrasonic phased array