N2 - We are developing a new Cs fountain frequency standard in NIM, and shooting for the frequency uncertainty of a few parts in 1016. The new fountain will run in a lab with the temperature fluctuation of 0.3K, and no active temperature control system will be added outside the flight tube. Instead, an isothermal liner will be surrounded the flight tube. It is a special type of heat pipe, made of a thin layer of vacuum tube filled with pure water. The thermal conductivity of a glass isothermal liner is about 10 times higher than that of coppers. It also works like a low pass filter reducing the temperature fluctuations of the system. The advantage of using an isothermal liner is to make the temperature of the whole interrogation region more uniform and stable. With precision standard Pt thermometers measuring the temperatures of a few locations of the flight tube, the average temperature uncertainty is less than 50 mK. The frequency shift due to the blackbody radiation can be calculated, and the relative frequency shift due to black body radiation can reach down to 7.2E-17 of this new fountain clock. Key words: Fountain clock, blackbody radiation, heat pipe.
AB - We are developing a new Cs fountain frequency standard in NIM, and shooting for the frequency uncertainty of a few parts in 1016. The new fountain will run in a lab with the temperature fluctuation of 0.3K, and no active temperature control system will be added outside the flight tube. Instead, an isothermal liner will be surrounded the flight tube. It is a special type of heat pipe, made of a thin layer of vacuum tube filled with pure water. The thermal conductivity of a glass isothermal liner is about 10 times higher than that of coppers. It also works like a low pass filter reducing the temperature fluctuations of the system. The advantage of using an isothermal liner is to make the temperature of the whole interrogation region more uniform and stable. With precision standard Pt thermometers measuring the temperatures of a few locations of the flight tube, the average temperature uncertainty is less than 50 mK. The frequency shift due to the blackbody radiation can be calculated, and the relative frequency shift due to black body radiation can reach down to 7.2E-17 of this new fountain clock. Key words: Fountain clock, blackbody radiation, heat pipe.
UR - http://www.scopus.com/inward/record.url?scp=84893341297&partnerID=8YFLogxK
U2 - 10.1109/EFTF-IFC.2013.6702140
DO - 10.1109/EFTF-IFC.2013.6702140
M3 - Conference contribution
AN - SCOPUS:84893341297
SN - 9781479903429
T3 - 2013 Joint European Frequency and Time Forum and International Frequency Control Symposium, EFTF/IFC 2013
SP - 232
EP - 234
BT - 2013 Joint European Frequency and Time Forum and International Frequency Control Symposium, EFTF/IFC 2013
T2 - 2013 Joint European Frequency and Time Forum and International Frequency Control Symposium, EFTF/IFC 2013
Y2 - 21 July 2013 through 25 July 2013
ER -