TY - JOUR
T1 - Reducing Space Charge Effects in a Linear Ion Trap by Rhombic Ion Excitation and Ejection
AU - Zhang, Xiaohua
AU - Wang, Yuzhuo
AU - Hu, Lili
AU - Guo, Dan
AU - Fang, Xiang
AU - Zhou, Mingfei
AU - Xu, Wei
N1 - Publisher Copyright:
© 2016, American Society for Mass Spectrometry.
PY - 2016/7/1
Y1 - 2016/7/1
N2 - Space charge effects play important roles in ion trap operations, which typically limit the ion trapping capacity, dynamic range, mass accuracy, and resolving power of a quadrupole ion trap. In this study, a rhombic ion excitation and ejection method was proposed to minimize space charge effects in a linear ion trap. Instead of applying a single dipolar AC excitation signal, two dipolar AC excitation signals with the same frequency and amplitude but 90° phase difference were applied in the x- and y-directions of the linear ion trap, respectively. As a result, mass selective excited ions would circle around the ion cloud located at the center of the ion trap, rather than go through the ion cloud. In this work, excited ions were then axially ejected and detected, but this rhombic ion excitation method could also be applied to linear ion traps with ion radial ejection capabilities. Experiments show that space charge induced mass resolution degradation and mass shift could be alleviated with this method. For the experimental conditions in this work, space charge induced mass shift could be decreased by ~50%, and the mass resolving power could be improved by ~2 times at the same time. [Figure not available: see fulltext.]
AB - Space charge effects play important roles in ion trap operations, which typically limit the ion trapping capacity, dynamic range, mass accuracy, and resolving power of a quadrupole ion trap. In this study, a rhombic ion excitation and ejection method was proposed to minimize space charge effects in a linear ion trap. Instead of applying a single dipolar AC excitation signal, two dipolar AC excitation signals with the same frequency and amplitude but 90° phase difference were applied in the x- and y-directions of the linear ion trap, respectively. As a result, mass selective excited ions would circle around the ion cloud located at the center of the ion trap, rather than go through the ion cloud. In this work, excited ions were then axially ejected and detected, but this rhombic ion excitation method could also be applied to linear ion traps with ion radial ejection capabilities. Experiments show that space charge induced mass resolution degradation and mass shift could be alleviated with this method. For the experimental conditions in this work, space charge induced mass shift could be decreased by ~50%, and the mass resolving power could be improved by ~2 times at the same time. [Figure not available: see fulltext.]
KW - Ion trajectory simulation
KW - Linear ion trap
KW - Rhombic ion excitation
KW - Space charge effects
UR - http://www.scopus.com/inward/record.url?scp=84975746109&partnerID=8YFLogxK
U2 - 10.1007/s13361-016-1393-1
DO - 10.1007/s13361-016-1393-1
M3 - Article
AN - SCOPUS:84975746109
SN - 1044-0305
VL - 27
SP - 1256
EP - 1262
JO - Journal of the American Society for Mass Spectrometry
JF - Journal of the American Society for Mass Spectrometry
IS - 7
ER -