T1 - Pseudo-Multiple Reaction Monitoring (Pseudo-MRM) Mode on the "brick" Mass Spectrometer, Using the Grid-SWIFT Waveform
AU - Xu, Zuqiang
AU - Jiang, Ting
AU - Xu, Qian
AU - Zhai, Yanbing
AU - Li, Dayu
AU - Xu, Wei
N1 - Publisher Copyright:
© 2019 American Chemical Society.
PY - 2019/11/5
Y1 - 2019/11/5
N2 - Besides portability and increasingly improved performances, the ability of screening target analyte from complex compounds is a crucial function of miniature mass spectrometers, especially for in situ analysis. Selected reaction monitoring (SRM) and multiple reaction monitoring (MRM) operation modes are the most widely used mass spectrometry operation methods for target analyte quantitation. As a continuous effort to improve the analytical performances of the "brick" mass spectrometer, built in-house, pseudo-SRM and pseudo-MRM modes were realized on the linear ion trap mass analyzer in the device. A broadband excitation waveform in both time and frequency domains, namely, the Grid-SWIFT waveform, was constructed and compared with the conventional SWIFT waveform. By isolating target ions during the ion introduction period using the Grid-SWIFT waveform, target ions could be efficiently accumulated inside the ion trap without experiencing space charge effects and interferences from nontarget ions in the samples. As a result, not only the detection sensitivity of the target analyte could be increased, but also the quantitation accuracy over a relatively wide concentration range could be improved.
AB - Besides portability and increasingly improved performances, the ability of screening target analyte from complex compounds is a crucial function of miniature mass spectrometers, especially for in situ analysis. Selected reaction monitoring (SRM) and multiple reaction monitoring (MRM) operation modes are the most widely used mass spectrometry operation methods for target analyte quantitation. As a continuous effort to improve the analytical performances of the "brick" mass spectrometer, built in-house, pseudo-SRM and pseudo-MRM modes were realized on the linear ion trap mass analyzer in the device. A broadband excitation waveform in both time and frequency domains, namely, the Grid-SWIFT waveform, was constructed and compared with the conventional SWIFT waveform. By isolating target ions during the ion introduction period using the Grid-SWIFT waveform, target ions could be efficiently accumulated inside the ion trap without experiencing space charge effects and interferences from nontarget ions in the samples. As a result, not only the detection sensitivity of the target analyte could be increased, but also the quantitation accuracy over a relatively wide concentration range could be improved.
UR - http://www.scopus.com/inward/record.url?scp=85073116546&partnerID=8YFLogxK
U2 - 10.1021/acs.analchem.9b03315
DO - 10.1021/acs.analchem.9b03315
M3 - Article
C2 - 31560203
AN - SCOPUS:85073116546
SN - 0003-2700
VL - 91
SP - 13838
EP - 13846
JO - Analytical Chemistry
JF - Analytical Chemistry
IS - 21
ER -