Abstract

This paper investigates the problem of output-only modal parameter estimation of time-varying structures. A two-stage least square method for modal parameter estimation of time-varying structures is presented, consisting of a least square complex frequency-domain stage for the modal parameter estimation of all discrete time samples and a weighted least square stage for the estimation of continuous-time-represented modal parameters. This paper introduces a fuzzy-clustering-based approach for validating and sifting the modal parameters and develops four modal assurance criterion-based distance functions to improve the quality of clustering of operational mode shapes. Furthermore, the proposed method has been validated by a simulation example and a laboratory experiment.

Original languageEnglish
Pages (from-to)94-119
Number of pages26
JournalMechanical Systems and Signal Processing
Volume47
Issue number1-2
DOIs
Publication statusPublished - 3 Aug 2014

Keywords

  • Fuzzy clustering
  • Modal parameter estimation
  • Time-varying structure
  • Two-stage least square

Fingerprint

Dive into the research topics of 'Parametric modal identification of time-varying structures and the validation approach of modal parameters'. Together they form a unique fingerprint.