Abstract
In order to achieve stable operation of the free-piston engine generator, the forces status on the free-piston of the working process were analyzed. The results showed that the operation of the free-piston engine generator could be seen as a single degree of freedom damping system with forced excitations. Combining the energy conservation principle of the working process, the matching between the structure parameters and the performance parameters of free-piston engine generator was studied. Some necessary qualifications to achieve stable operation of the free-piston engine generator were obtained through coupling analysis calculation by using an energy equilibrium method. The analysis conclusion was validated on a prototype by simulation. The results showed that the movement of free-piston could reach stable operation approximately, and the coupling analysis method proposed was reasonable.
Original language | English |
---|---|
Pages (from-to) | 1-5 |
Number of pages | 5 |
Journal | Nongye Jixie Xuebao/Transactions of the Chinese Society for Agricultural Machinery |
Volume | 44 |
Issue number | 7 |
DOIs | |
Publication status | Published - Jul 2013 |
Keywords
- Energy equilibrium
- Engine generator
- Free-piston
- Parameters coupling
- Stable operation