TY - JOUR
T1 - Nonwoven polypropylene as a novel extractant phase holder for the determination of insecticides in environmental water samples
AU - Hu, Lu
AU - Li, Songqing
AU - Zhang, Panjie
AU - Yang, Xiaoling
AU - Yang, Miyi
AU - Lu, Runhua
AU - Gao, Haixiang
N1 - Publisher Copyright:
© 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim
PY - 2014/9
Y1 - 2014/9
N2 - In this work, a novel liquid-phase microextraction approach using nonwoven polypropylene as the extraction solvent holder was developed. Nonwoven polypropylene, a hydrophobic material, is widely used in the cleanup of oil spills. Due to its large surface area, efficient, and full extraction can be achieved. Nonwoven polypropylene containing an ionic liquid was used to extract benzoylurea insecticides (diflubenzuron, teflubenzuron, flufenoxuron, and chlorfluazuron) through vortex-assisted liquid - liquid microextraction. The parameters that affected the extraction efficiency included the type and volume of the extractant, the extraction time, the time and solvent volume for desorption and the mass and surface area of the nonwoven polypropylene. Under the optimized conditions, good linearity was obtained, with coefficients of determination greater than 0.9996, and the limit of detections of these compounds, calculated at S/N = 3, were in the range of 0.73-5.0 ng/mL. The recoveries of the four insecticides at two spiked levels ranged from 93.3 to 102.0%, with relative standard deviations of less than 4.0%. The proposed method was then successfully used for the rapid determination of benzoylurea insecticides in spiked real water samples before liquid chromatographic analysis. The procedure is simple, inexpensive, easy to execute, and can be widely used.
AB - In this work, a novel liquid-phase microextraction approach using nonwoven polypropylene as the extraction solvent holder was developed. Nonwoven polypropylene, a hydrophobic material, is widely used in the cleanup of oil spills. Due to its large surface area, efficient, and full extraction can be achieved. Nonwoven polypropylene containing an ionic liquid was used to extract benzoylurea insecticides (diflubenzuron, teflubenzuron, flufenoxuron, and chlorfluazuron) through vortex-assisted liquid - liquid microextraction. The parameters that affected the extraction efficiency included the type and volume of the extractant, the extraction time, the time and solvent volume for desorption and the mass and surface area of the nonwoven polypropylene. Under the optimized conditions, good linearity was obtained, with coefficients of determination greater than 0.9996, and the limit of detections of these compounds, calculated at S/N = 3, were in the range of 0.73-5.0 ng/mL. The recoveries of the four insecticides at two spiked levels ranged from 93.3 to 102.0%, with relative standard deviations of less than 4.0%. The proposed method was then successfully used for the rapid determination of benzoylurea insecticides in spiked real water samples before liquid chromatographic analysis. The procedure is simple, inexpensive, easy to execute, and can be widely used.
KW - Benzoylurea insecticides
KW - Liquid chromatography
KW - Microextraction
KW - Nonwoven polypropylene
UR - http://www.scopus.com/inward/record.url?scp=84908354260&partnerID=8YFLogxK
U2 - 10.1002/jssc.201400459
DO - 10.1002/jssc.201400459
M3 - Article
C2 - 24947661
AN - SCOPUS:84908354260
SN - 1615-9306
VL - 37
SP - 2545
EP - 2551
JO - Journal of Separation Science
JF - Journal of Separation Science
IS - 18
ER -