TY - GEN
T1 - Measurement of refractive index and liquid diffusion coefficient based on focal plane imaging method
AU - Wei, Li
AU - Gao, Haifeng
AU - Zhou, Haitao
AU - Cheng, Dewen
N1 - Publisher Copyright:
© 2022 SPIE. All rights reserved.
PY - 2022
Y1 - 2022
N2 - Liquid-core cylindrical lens (LCL) is glued together by two cylindrical lenses, translucent liquid with refractive index n is injected into the liquid core, based on focal plane imaging method, the refractive index n has a one-to-one dependence on the focal length f of the LCL, n= f(n). Two kind of LCL, symmetrical liquid-core cylindrical lens (SLCL) and asymmetrical liquid-core cylindrical lens (ALCL) had been designed and fabricated, the refractive index measurement accuracy is superior to 0.0002 RIU. Based on the refractive index spatial measurement capability of ALCL, the equivalent refractive index thin layer movement method for rapidly and accurately measuring the diffusion coefficient D under the infinite dilution condition was applied to measure an aqueous CaCl2 solution at temperature of 303 K, and the result D were simulated and verified by ray tracing method. Comparing with the traditional method, this method has the advantages of visualization of diffusion process, strong anti-interference capability, rapid measurement, which can be widely used in medical, chemical, biological, environmental protection or other fields.
AB - Liquid-core cylindrical lens (LCL) is glued together by two cylindrical lenses, translucent liquid with refractive index n is injected into the liquid core, based on focal plane imaging method, the refractive index n has a one-to-one dependence on the focal length f of the LCL, n= f(n). Two kind of LCL, symmetrical liquid-core cylindrical lens (SLCL) and asymmetrical liquid-core cylindrical lens (ALCL) had been designed and fabricated, the refractive index measurement accuracy is superior to 0.0002 RIU. Based on the refractive index spatial measurement capability of ALCL, the equivalent refractive index thin layer movement method for rapidly and accurately measuring the diffusion coefficient D under the infinite dilution condition was applied to measure an aqueous CaCl2 solution at temperature of 303 K, and the result D were simulated and verified by ray tracing method. Comparing with the traditional method, this method has the advantages of visualization of diffusion process, strong anti-interference capability, rapid measurement, which can be widely used in medical, chemical, biological, environmental protection or other fields.
KW - Liquid-core cylindrical lens
KW - liquid diffusion coefficient
KW - optical measurement
KW - refractive index
UR - http://www.scopus.com/inward/record.url?scp=85141799709&partnerID=8YFLogxK
U2 - 10.1117/12.2636005
DO - 10.1117/12.2636005
M3 - Conference contribution
AN - SCOPUS:85141799709
T3 - Proceedings of SPIE - The International Society for Optical Engineering
BT - Current Developments in Lens Design and Optical Engineering XXIII
A2 - Johnson, R. Barry
A2 - Mahajan, Virendra N.
A2 - Thibault, Simon
A2 - Padilla-Vivanco, Alfonso
PB - SPIE
T2 - Current Developments in Lens Design and Optical Engineering XXIII 2022
Y2 - 23 August 2022 through 24 August 2022
ER -