TY - JOUR
T1 - Low dose detection of γ radiation via solvent assisted fluorescence quenching
AU - Han, Ji Min
AU - Xu, Miao
AU - Wang, Brian
AU - Wu, Na
AU - Yang, Xiaomei
AU - Yang, Haori
AU - Salter, Bill J.
AU - Zang, Ling
PY - 2014/4/2
Y1 - 2014/4/2
N2 - Development of low cost, easy-to-use chemical sensor systems for low dose detection of radiation remains highly desired for medical radiation therapy and nuclear security monitoring. We report herein on a new fluorescence sensor molecule, 4,4'-di(1H-phenanthro[9,10-d]imidazol-2-yl)biphenyl (DPI-BP), which can be dissolved into halogenated solvents (e.g., CHCl3, CH 2Cl2) to enable instant detection of radiation down to the 0.01 Gy level. The sensing mechanism is primarily based on radiation induced fluorescence quenching of DPI-BP. Pristine DPI-BP is strongly fluorescent in halogenated solvents. When exposed to radiation, the halogenated solvents decompose into various radicals, including hydrogen and chlorine, which then combine to produce hydrochloric acid (HCl). This strong acid interacts with the imidazole group of DPI-BP to convert it into a DPI-BP/HCl adduct. The DPI-BP/HCl adduct possesses a more planar configuration than DPI-BP, enhancing the π-π stacking and thus molecular aggregation. The strong molecular fluorescence of DPI-BP gets quenched upon aggregation, due to the π-π stacking interaction (forming forbidden low-energy excitonic transition). Interestingly the quenched fluorescence can be recovered simply by adding base (e.g., NaOH) into the solution to dissociate the DPI-BP/HCl adduct. Such sensing mechanism was supported by systematic investigations based on HCl titration and dynamic light scattering measurements. To further confirm that the aggregation caused fluorescence quenching, a half size analogue of DPI-BP, 2-phenyl-1H-phenanthro[9,10-d]imidazole (PI-Ph), was synthesized and investigated in comparison with the observations of DPI-BP. PI-Ph shares the same imidazole conjugation structure with DPI-BP and is expected to bind the same way with HCl. However, PI-Ph did not show fluorescence quenching upon binding with HCl likely due to the smaller π-conjugation structure, which can hardly enforce the π-π stacking assembly. Combining the low detection limit, fast and reversible fluorescence quenching response, and low cost of halogenated solvent composites, the sensor system presented may lead to the development of new, simple chemical dosimetry for low dose detection of γ radiation.
AB - Development of low cost, easy-to-use chemical sensor systems for low dose detection of radiation remains highly desired for medical radiation therapy and nuclear security monitoring. We report herein on a new fluorescence sensor molecule, 4,4'-di(1H-phenanthro[9,10-d]imidazol-2-yl)biphenyl (DPI-BP), which can be dissolved into halogenated solvents (e.g., CHCl3, CH 2Cl2) to enable instant detection of radiation down to the 0.01 Gy level. The sensing mechanism is primarily based on radiation induced fluorescence quenching of DPI-BP. Pristine DPI-BP is strongly fluorescent in halogenated solvents. When exposed to radiation, the halogenated solvents decompose into various radicals, including hydrogen and chlorine, which then combine to produce hydrochloric acid (HCl). This strong acid interacts with the imidazole group of DPI-BP to convert it into a DPI-BP/HCl adduct. The DPI-BP/HCl adduct possesses a more planar configuration than DPI-BP, enhancing the π-π stacking and thus molecular aggregation. The strong molecular fluorescence of DPI-BP gets quenched upon aggregation, due to the π-π stacking interaction (forming forbidden low-energy excitonic transition). Interestingly the quenched fluorescence can be recovered simply by adding base (e.g., NaOH) into the solution to dissociate the DPI-BP/HCl adduct. Such sensing mechanism was supported by systematic investigations based on HCl titration and dynamic light scattering measurements. To further confirm that the aggregation caused fluorescence quenching, a half size analogue of DPI-BP, 2-phenyl-1H-phenanthro[9,10-d]imidazole (PI-Ph), was synthesized and investigated in comparison with the observations of DPI-BP. PI-Ph shares the same imidazole conjugation structure with DPI-BP and is expected to bind the same way with HCl. However, PI-Ph did not show fluorescence quenching upon binding with HCl likely due to the smaller π-conjugation structure, which can hardly enforce the π-π stacking assembly. Combining the low detection limit, fast and reversible fluorescence quenching response, and low cost of halogenated solvent composites, the sensor system presented may lead to the development of new, simple chemical dosimetry for low dose detection of γ radiation.
UR - http://www.scopus.com/inward/record.url?scp=84897542752&partnerID=8YFLogxK
U2 - 10.1021/ja500262n
DO - 10.1021/ja500262n
M3 - Article
C2 - 24611651
AN - SCOPUS:84897542752
SN - 0002-7863
VL - 136
SP - 5090
EP - 5096
JO - Journal of the American Chemical Society
JF - Journal of the American Chemical Society
IS - 13
ER -