Zhang, H., He, J., Hou, W., Fang, X., Li, J., Feng, B., Xu, Z., Wang, J., Wu, X., Zhao, Z., Wu, B., & Chen, C. (1999). LBO type-I noncritical phase-matched intracavity frequency-doubled 671 nm laser. Guangxue Xuebao/Acta Optica Sinica, 19(10), 1323-1326.
Zhang, Hengli ; He, Jingliang ; Hou, Wei et al. / LBO type-I noncritical phase-matched intracavity frequency-doubled 671 nm laser. In: Guangxue Xuebao/Acta Optica Sinica. 1999 ; Vol. 19, No. 10. pp. 1323-1326.
@article{9ef30af6675f406aaafacd1f7ce611b8,
title = "LBO type-I noncritical phase-matched intracavity frequency-doubled 671 nm laser",
abstract = "With a type-I noncritical phase-matched LBO crystal as the intracavity frequency doubler in a LD pumped Nd:YVO4 laser, a 671 nm laser output of 240 mW was obtained with 5.44 W absorbed pump power, and the optical-optical conversion efficiency is 4.4%. When the laser output is 150 mW, the short-period instability of laser output is less than 2.7%. The laser output can be increased by improving the temperature control of LBO crystal.",
author = "Hengli Zhang and Jingliang He and Wei Hou and Xiaojun Fang and Jian Li and Baohua Feng and Zuyan Xu and Jianming Wang and Xing Wu and Zongyuan Zhao and Baichang Wu and Chuangtian Chen",
year = "1999",
month = oct,
language = "English",
volume = "19",
pages = "1323--1326",
journal = "Guangxue Xuebao/Acta Optica Sinica",
issn = "0253-2239",
publisher = "Chinese Optical Society",
number = "10",
}
Zhang, H, He, J, Hou, W, Fang, X, Li, J, Feng, B, Xu, Z, Wang, J, Wu, X, Zhao, Z, Wu, B & Chen, C 1999, 'LBO type-I noncritical phase-matched intracavity frequency-doubled 671 nm laser', Guangxue Xuebao/Acta Optica Sinica, vol. 19, no. 10, pp. 1323-1326.
LBO type-I noncritical phase-matched intracavity frequency-doubled 671 nm laser. /
Zhang, Hengli; He, Jingliang; Hou, Wei et al.
In:
Guangxue Xuebao/Acta Optica Sinica, Vol. 19, No. 10, 10.1999, p. 1323-1326.
Research output: Contribution to journal › Article › peer-review
TY - JOUR
T1 - LBO type-I noncritical phase-matched intracavity frequency-doubled 671 nm laser
AU - Zhang, Hengli
AU - He, Jingliang
AU - Hou, Wei
AU - Fang, Xiaojun
AU - Li, Jian
AU - Feng, Baohua
AU - Xu, Zuyan
AU - Wang, Jianming
AU - Wu, Xing
AU - Zhao, Zongyuan
AU - Wu, Baichang
AU - Chen, Chuangtian
PY - 1999/10
Y1 - 1999/10
N2 - With a type-I noncritical phase-matched LBO crystal as the intracavity frequency doubler in a LD pumped Nd:YVO4 laser, a 671 nm laser output of 240 mW was obtained with 5.44 W absorbed pump power, and the optical-optical conversion efficiency is 4.4%. When the laser output is 150 mW, the short-period instability of laser output is less than 2.7%. The laser output can be increased by improving the temperature control of LBO crystal.
AB - With a type-I noncritical phase-matched LBO crystal as the intracavity frequency doubler in a LD pumped Nd:YVO4 laser, a 671 nm laser output of 240 mW was obtained with 5.44 W absorbed pump power, and the optical-optical conversion efficiency is 4.4%. When the laser output is 150 mW, the short-period instability of laser output is less than 2.7%. The laser output can be increased by improving the temperature control of LBO crystal.
UR - http://www.scopus.com/inward/record.url?scp=0033206660&partnerID=8YFLogxK
M3 - Article
AN - SCOPUS:0033206660
SN - 0253-2239
VL - 19
SP - 1323
EP - 1326
JO - Guangxue Xuebao/Acta Optica Sinica
JF - Guangxue Xuebao/Acta Optica Sinica
IS - 10
ER -
Zhang H, He J, Hou W, Fang X, Li J, Feng B et al. LBO type-I noncritical phase-matched intracavity frequency-doubled 671 nm laser. Guangxue Xuebao/Acta Optica Sinica. 1999 Oct;19(10):1323-1326.