TY - JOUR
T1 - Ion collision cross section analyses in quadrupole ion traps using the filter diagonalization method
T2 - A theoretical study
AU - Jiang, Ting
AU - He, Miyi
AU - Guo, Dan
AU - Zhai, Yanbing
AU - Xu, Wei
N1 - Publisher Copyright:
© 2016 the Owner Societies.
PY - 2016
Y1 - 2016
N2 - Previously, we have demonstrated the feasibility of measuring ion collision cross sections (CCSs) within a quadrupole ion trap by performing time-frequency analyses of simulated ion trajectories. In this study, an improved time-frequency analysis method, the filter diagonalization method (FDM), was applied for data analyses. Using the FDM, high resolution could be achieved in both time- and frequency-domains when calculating ion time-frequency curves. Owing to this high-resolution nature, ion-neutral collision induced ion motion frequency shifts were observed, which further cause the intermodulation of ion trajectories and thus accelerate image current attenuation. Therefore, ion trap operation parameters, such as the ion number, high-order field percentage and buffer gas pressure, were optimized for ion CCS measurements. Under optimized conditions, simulation results show that a resolving power from 30 to more than 200 could be achieved for ion CCS measurements.
AB - Previously, we have demonstrated the feasibility of measuring ion collision cross sections (CCSs) within a quadrupole ion trap by performing time-frequency analyses of simulated ion trajectories. In this study, an improved time-frequency analysis method, the filter diagonalization method (FDM), was applied for data analyses. Using the FDM, high resolution could be achieved in both time- and frequency-domains when calculating ion time-frequency curves. Owing to this high-resolution nature, ion-neutral collision induced ion motion frequency shifts were observed, which further cause the intermodulation of ion trajectories and thus accelerate image current attenuation. Therefore, ion trap operation parameters, such as the ion number, high-order field percentage and buffer gas pressure, were optimized for ion CCS measurements. Under optimized conditions, simulation results show that a resolving power from 30 to more than 200 could be achieved for ion CCS measurements.
UR - http://www.scopus.com/inward/record.url?scp=84966267422&partnerID=8YFLogxK
U2 - 10.1039/c6cp00613b
DO - 10.1039/c6cp00613b
M3 - Article
AN - SCOPUS:84966267422
SN - 1463-9076
VL - 18
SP - 12058
EP - 12064
JO - Physical Chemistry Chemical Physics
JF - Physical Chemistry Chemical Physics
IS - 17