TY - JOUR
T1 - Instant water toxicity detection based on magnetically-constructed electrochemically active biofilm
AU - Zhao, Hongyu
AU - Zang, Yuxuan
AU - Xie, Beizhen
AU - Zhao, Ting
AU - Cao, Bo
AU - Wu, Jing
AU - Ge, Yanhong
AU - Yi, Yue
AU - Liu, Hong
N1 - Publisher Copyright:
© 2023 Elsevier B.V.
PY - 2023/12/15
Y1 - 2023/12/15
N2 - Water toxicity determination with electrochemically active bacteria (EAB) is promising in the early warning of water pollution. However, limited by tedious biofilm formation, natural EAB biofilms are uncapable of the instant detection of water toxicity, resulting in the failure for the emergency monitoring of water pollution. To solve this problem, a novel method for the rapid construction of EAB biofilms using magnetic adsorption was established, and the performance of instant water toxicity detection with magnetically-constructed EAB biofilm was investigated. The results demonstrate that EAB biofilms were magnetically constructed in less than 30 min, and magnetically-constructed EAB biofilm generated stable currents even under continuous flow conditions. Magnetically-constructed EAB biofilms realized instant water toxicity detection, and the sensitivity increased with the decrease of magnetic field intensity. Low magnetic field intensity resulted in a loose biofilm structure, which is conducive to toxic pollutant penetration. The detection limit for Cu2+, phenol, and Cd2+ achieved 0.07 mg/L with optimal magnetic field intensity, and the detection time was less than 30 min. This study broadens the application of water toxicity determination with EAB, and establishes a foundation for the instant and continuous detection of water toxicity with EAB.
AB - Water toxicity determination with electrochemically active bacteria (EAB) is promising in the early warning of water pollution. However, limited by tedious biofilm formation, natural EAB biofilms are uncapable of the instant detection of water toxicity, resulting in the failure for the emergency monitoring of water pollution. To solve this problem, a novel method for the rapid construction of EAB biofilms using magnetic adsorption was established, and the performance of instant water toxicity detection with magnetically-constructed EAB biofilm was investigated. The results demonstrate that EAB biofilms were magnetically constructed in less than 30 min, and magnetically-constructed EAB biofilm generated stable currents even under continuous flow conditions. Magnetically-constructed EAB biofilms realized instant water toxicity detection, and the sensitivity increased with the decrease of magnetic field intensity. Low magnetic field intensity resulted in a loose biofilm structure, which is conducive to toxic pollutant penetration. The detection limit for Cu2+, phenol, and Cd2+ achieved 0.07 mg/L with optimal magnetic field intensity, and the detection time was less than 30 min. This study broadens the application of water toxicity determination with EAB, and establishes a foundation for the instant and continuous detection of water toxicity with EAB.
KW - Biofilm formation
KW - Electrochemically active bacteria
KW - Magnetic force
KW - Microbial electrochemical system
KW - Water toxicity determination
UR - http://www.scopus.com/inward/record.url?scp=85173588485&partnerID=8YFLogxK
U2 - 10.1016/j.bios.2023.115745
DO - 10.1016/j.bios.2023.115745
M3 - Article
C2 - 37832348
AN - SCOPUS:85173588485
SN - 0956-5663
VL - 242
JO - Biosensors and Bioelectronics
JF - Biosensors and Bioelectronics
M1 - 115745
ER -